Troubleshooting
Review troubleshooting tasks for common issues.
Configure per-connection log level
When you troubleshoot a connection or want to limit unnecessary logging, you can configure a log level that applies only to that connection without affecting the global log settings.
Collect a trace log for a connection
Use the Override Log Level option to collect a trace log for a single connection. You can review the trace log to debug the connection or upload the log to a support case.
- On the Connect Overview page, go to the Connections section. Click a connection, and then click Edit.
- In the General Information section, expand Advanced.
- Select Override Log Level to temporarily capture detailed log output for a set number of connection runs.
- Set Temporary Log Level to Trace.
- Set Number of Runs to 5.
- Click Save and Run.
- After the connection runs complete, click Download
to the right of the connection log.
- Review the trace log or upload the log to a support case.
For more information about the Override Log Level option, see Configure per-connection log level.
Test connections
You might have trouble running a connection for one of the following reasons:
-
The API token that Connect uses to run the connection was manually deleted or rotated
-
The user who owns the connection no longer has access to the connection
-
The persona used to run or schedule the connection is no longer associated with a user
You can sign in as the user that owns the connection and view the Connect Overview page, then run the connection outside of the scheduled intervals.
Troubleshoot issues
Issue: Connection fails
There are multiple reasons that might cause connections to fail. When a connection fails, review the log of the connection to determine the reason why the connection failed:
-
From the Main menu, go to .
-
In the row of the connection that failed, click the date in the Last Run Status column.
-
Expand the log for a failed run to review any errors.
Alternatively, click Download
and review the log in your preferred editor.
Destination not included in the network egress allow list
Before your connections can successfully send data to a destination, your Tanium Cloud instance, network egress allow list, and network allow list must be configured. Note the following:
-
Sign in to your Tanium Account and configure a network egress allow list rule for each destination fully qualified domain name (FQDN) and associated port. For more information about how to configure the network egress allow list, see Configuring network egress for Tanium Cloud.
-
Review cloud egress destinations and ports to ensure that a destination FQDN and associated port are in the network egress allow list.
-
TCP traffic that does not use Server Name Indication (SNI) is limited to one destination per port. For example, SQL traffic and SMTP traffic do not use SNI.
-
TCP traffic is not supported for the following ports: 22, 25, 111, 3128, 3129, 3130, 4000, 5000, 6000, 9100, 9301, 9302, 9901, and 9902.
-
UDP traffic is not supported.
-
Your Tanium Cloud instance has a proxy cluster with 2 public IP addresses. If the destination is in your network, add inbound traffic from these IP addresses to your network allow list.
For more information, see Network egress. For assistance, contact Tanium Support.
Connection reached memory ceiling
Connect has a global memory ceiling of 8GB for all connections in addition to an individual limit that you can configure for each connection.
Symptom
When a connection reaches its individual memory ceiling, a message similar to the following appears in the run log:
The connection process aborted (exit code 134), most likely because it ran out of memory at its memory ceiling of 1 GB.
Resolution
Potential resolutions include the following:
-
Add filters to the connection to reduce the amount of data sent in the connection. For more information, see Reference: Filtering options.
-
Increase the memory ceiling of the connection.
-
From the Main menu, go to .
-
Click the name of the connection to view details for the connection, and then click Edit.
-
In the General Information section, expand the Advanced sub-section.
-
Edit the Memory Ceiling as necessary and then click Save.
-
Issue: <no value> in Tanium Data Service (TDS) output
-
Verify that the sensor for the saved question is registered with TDS. For more information, see View sensor registration details.
-
If the sensor is not registered, register it for collection. For more information, see Register or unregister sensors for collection.
Issue: Connection does not export all intended data
Connections use the role permissions of the owner to access content. If the connection owner has insufficient permission for content that a connection requires, such as inability to view a computer group, the connection might not fully export the data that you intend to export.
To resolve, update the owner's permissions to allow access to intended content. For more information and descriptions of content sets and permissions, see RBAC overview.
Issue: Columns are missing from the Microsoft Azure Monitor table
Symptom
After a connection run completes successfully, one or more columns are missing from the custom table in Microsoft Azure Monitor. Connect does not report an error.
Cause
The streamDeclarations.columns array in your data collection rule (DCR) does not include all columns that Connect is sending. Microsoft Azure silently drops any column that is not declared in streamDeclarations.columns before the transformation runs. No error is logged on either the Connect or Microsoft Azure side.
Resolution
Add the missing columns to both streamDeclarations.columns in the DCR and the Microsoft Azure Monitor table schema. The columns in streamDeclarations.columns must match your Connect connection output configuration exactly. For more information, see Configure the Microsoft Azure Monitor destination.
|
Symptom |
Cause |
Resolution |
|---|---|---|
|
Some columns are missing from the Azure Monitor table |
streamDeclarations.columns does not list those columns |
Add the missing columns to streamDeclarations.columns and to the table schema |
|
Only TimeGenerated and Type appear in the table, with no custom data |
streamDeclarations.columns has no custom columns defined |
Add all Connect output columns to streamDeclarations.columns and the table schema |
Issue: Scheduled connection owned by a deleted user no longer runs
Scheduled connections require an existing Tanium user account owner to run scheduled instances. If the scheduled connection owner is deleted, future scheduled instances of that connection do not run.
To resolve, export and import the scheduled connection to create a new scheduled connection. For more information, see Export connections and Import connections.
Issue: Tanium Audit Source connection fails with MaxNumberOfAuditEntriesPerCacheExceeded error
Connections configured with the Tanium Audit Source connection source might fail if you configure Days of History Retrieved as 0 or a very large value, and a large period of time elapses between connection runs. Update the Days of History Retrieved value to a small integer, such as 1 or 2. For more information, see Reference: Tanium Audit Source data.
Issue: Emails to Microsoft 365 destinations fail to send
Emails sent to Microsoft 365 destinations are subject to the following limitations:
-
The Email (O365) destination requires an email server profile. If you delete an email server profile configuration that is referenced by a scheduled connection, future scheduled instances of that connection fail. Recreate the email server profile configuration, then reference the new email server profile in the scheduled connection.
-
The Microsoft Graph API limits email requests to four concurrent requests. If you have multiple connections using the same email server profile configuration, emails over the four concurrent requests are queued for sending after prior requests resolve. Schedule connections using the same email server profile configuration to run at different times and minimize the number of requests sent simultaneously.
-
If you assign the Mail.Read permission to your Microsoft Entra ID (formerly Azure Active Directory) application, you can send emails with attachments up to a total of 3 MB, or emails with a body up to 3 MB. If your connections send more data than that per run, do one of the following:
-
Schedule your connection to run more frequently, to try and reduce the size of each email.
-
Refine the connection source configuration to reduce the amount of data sent per connection run.
-
Assign the Mail.ReadWrite permission to the Microsoft Entra ID application. This enables sending emails with attachments up to a total of 150 MB, subject to any other limits that you configure in your Azure environment.
-
Issue: Imported connections to Microsoft 365 destinations do not run
Exporting a connection that uses a Microsoft 365 destination from one environment and importing it in another does not also import the required email server profile configuration. To export a connection that uses a Microsoft 365 destination:
-
Export the connection from the originating environment, then import the connection in the target environment. For more information, see Export connections and Import connections.
-
Create the email server profile in the target environment. For more information, see Configure email server profile settings for Microsoft 365.
-
Edit the connection and select the Email Server Profile. For more information, see Configure the email results destination.
Issue: Created connection does not allow editing of source or destination type
After you create a connection, you cannot update the connection source type or destination type, only the source configuration or destination configuration. If you want to change the source type or destination type, create a new connection.
Issue: Cannot authenticate connection to Splunk instance using HTTP destination
Connections to Splunk instances that use the HTTP destination cannot authenticate against the Splunk instance unless Splunk and a space precede the token string. Configure an HTTP header named Authorization. Then configure an HTTP header value in the format Splunk <token-string>.
-
From the Create Connection page, enter a Name and select a Source. Then select HTTP as the Destination.
-
Select Header Authentication from Use Authentication.
-
Enter Authorization in the Auth Header Name field.
-
Enter the Splunk token string in the Secret field, using the format Splunk <token-string>.
-
Enter other information required for the connection.
-
Click Save.
Issue: When configuring an SQL Server connection that uses a satellite, the action might time out when retrieving properties
When you create or edit a connection that uses a satellite to send data to an on-premises SQL Server destination, the following message appears when you click Retrieve Properties:
The action has timed out. Try again later or look for more information in Tanium Connect User Guide: Troubleshoot issue
Cause
This message appears if an error occurs between Connect and the SQL Server, or if the connection to AWS or Microsoft Azure times out.
Resolution
Possible resolutions include:
-
Try to click Retrieve Properties again.
-
Select a different satellite to connect to the on-premises destination.
-
Create an isolated subnet for the satellite. Satellites that are not in isolated subnets might operate slower and cause timeouts. For information about how to configure an isolated subnet, see Configure isolated subnets.
Issue: When you run a connection to an SQL Server destination that uses a satellite, the sign-in fails to open server "127.0.0.1"
When you connect to an SQL Server destination through a satellite proxy with encryption enabled, the following authentication error appears:
Cannot open server "127.0.0.1" requested by the login. The login failed.
Cause
This error occurs because the connection configuration uses 127.0.0.1 (the local proxy address), but the serverName in dialectOptions on the SQL Server contains the original server name. This mismatch causes SQL Server authentication failures when encryption is enabled.
Resolution
Use the user@servername format for the SQL Server username to bypass the authentication error.
-
Sign in to Tanium Console.
-
From the Main menu, go to . Go to the Connections section, click the SQL Server connection, and click Edit.
-
Update the User Name field to include the server name in the format: username@servername.
For example, if your username is Tanium and your server is foo.database.windows.net, change the username to Tanium@foo.database.windows.net.
-
Click Save and Run to save the configuration and test the connection.
Contact Tanium Support
To contact Tanium Support for help, sign in to the Tanium Customer Community.
For more information about submitting a support case, see Case Submission Form.