Configuring email destinations

Important:

Before your connections can successfully send data to a destination, your Tanium Cloud instance, network egress allow list, and network allow list must be configured. Note the following:

  • Managing your Tanium Account and configure a network egress allow list rule for each destination fully qualified domain name (FQDN) and associated port. For more information about how to configure the network egress allow list, see Configuring network egress for Tanium Cloud.

  • You must associate a port used for non-HTTPS destinations with only one FQDN. If multiple FQDNs are associated with the same port, traffic does not route correctly.

  • TCP traffic that does not use Server Name Indication (SNI) is limited to one destination per port. For example, SQL traffic and SMTP traffic do not use SNI.

  • TCP traffic is not supported for the following ports: 22, 25, 111, 3128, 3129, 3130, 4000, 5000, 6000, 9100, 9301, 9302, 9901, and 9902.

  • UDP traffic is not supported.

  • Your Tanium Cloud instance has a proxy cluster with 2 public IP addresses. If a destination is in your network, add inbound traffic from these IP addresses to your network allow list.

For more information, including restrictions on FQDNs and ports, see Network egress. For assistance, Contact Tanium Support.

You can send information from a connection source to a set of email addresses using Microsoft 365 email resources or through an SMTP server. You can either include the results in the email body, or create an attachment.

Note: Microsoft 365 was previously known as Office 365 (O365).

Prerequisites for Microsoft 365 destinations

To configure a connection destination to send email through Microsoft 365, ensure you complete the following prerequisites:

  • For a walkthrough of configuration prerequisites, Microsoft Azure configuration, email server profile configuration, and connection configuration, see Tanium Community: Use Tanium Connect to Send Microsoft Office 365 Emails using Modern Authentication.

  • You must have a Microsoft 365 Outlook email address associated with a Microsoft Entra ID (formerly Azure Active Directory) user.

  • You must create a Microsoft Entra ID application and service principal, and assign the Mail.Send and User.Read permissions to the application, to send an email with an attachment up to a total of 3 MB (this includes the body of the email plus the attachment). If you want to limit the application scope, create an application access policy and associate it with a mail-enabled security group containing at least one user. For more information, see Microsoft Entra documentation: Create a Microsoft Entra application and service principal that can access resources and Microsoft Graph documentation: Configure ApplicationAccessPolicy.

    • You must also generate a Microsoft Entra ID application client secret. For more information, see Microsoft Entra documentation: Option 3: Create a new client secret.

    • You must also assign the Mail.Send and User.Read permissions to the application to send emails with attachments up to a total of 3 MB. For more information, see Microsoft Entra documentation: Assign a role to the application.

      Note: If a connection run generates no data, no email is sent. However, if you select a saved question source and clear Hide No Results, an email is sent per connection run, regardless of whether data is available.
    • If you want to enable sending emails with attachments greater than 3 MB and up to 150 MB (subject to your Microsoft 365 attachment settings), you can assign the Mail.ReadWrite permission to the Microsoft Entra ID application. If you assign this permission, you must allow traffic to outlook.office.com over port 443/TCP and outlook.office365.com over port 443/TCP.

      Important: Attachments larger than 3 MB are not supported for email sent through GCC M365, including FedRAMP M365. Connect uses the Microsoft createUploadSession API to manage attachments for Microsoft 365 email uploads. The API has a known issue with attachments larger than 3 MB in GCC M365 environments. This limitation applies to any customer whose Microsoft 365 environment is GCC M365, independent of the Tanium environment. Customers who try to send an email with an attachment larger than 3 MB through a GCC M365 environment might receive a MS_GRAPH_STATUS_CODE 401 large_attachment response that contains an error message similar to caused by unexpected status code 401 from ms-graph. For more information about the createUploadSession API and the known issue, see Microsoft Graph documentation: attachment: createUploadSession.
      Note: The Mail.ReadWrite permission only permits a larger attachment size; the body of the email must never exceed 3 MB.
      Note: For the best results, if you assign the Mail.ReadWrite permission, create an access policy and limit Microsoft Entra ID application access to one user. For more information, see Microsoft Graph documentation: Limiting application permissions to specific Exchange Online mailboxes.
  • The Email (O365 & SMTP) destination requires an email server profile on Tanium Cloud. You can configure an email server profile through the Connect workbench in Tanium Console.

    • To configure an email server profile in Tanium Console, you must have a role with the Tanium Email Config write permission. The predefined Connect Operator role in Connect has this permission. Sending an email requires the user that configures the connection to have permission to the content set to which you assign the email server profile. For more information about predefined roles in Connect, see User role requirements. For information about configuring custom roles, see Managing roles

    Note: If you delete an email server profile configuration that is referenced by a scheduled connection, future scheduled instances of that connection fail. For more information, see Issue: Emails to Microsoft 365 destinations fail to send.
  • The email server profile uses the Authority Host that you select for authentication to the Host that you select, over port 443/TCP.

  • Configure a network egress allow list rule for the following Microsoft 365 URLs to enable access for Microsoft 365 mail resources:

    • graph.microsoft.com:443

    • login.microsoftonline.com:443

    • graph.microsoft.us:443

    • dod-graph.microsoft.us:443 for DoD tenants

    • login.microsoftonline.us:443

    • outlook.office.com:443 and if you assign the Mail.ReadWrite permission to the Microsoft Entra ID application. For more information, see Microsoft 365 documentation: Office 365 URLs and IP address ranges.

    To configure network egress allow list rules, see Configuring network egress for Tanium Cloud.

For more information about how to configure an email server profile, see Configure email server profile settings for Microsoft 365.

Prerequisites for SMTP destinations

  • The Email (O365 & SMTP) destination requires an email server profile on Tanium Cloud. You can configure an email server profile through the Connect workbench in Tanium Console.

    • To configure an email server profile in Tanium Console, you must have a role with the Tanium Email Config write permission. The predefined Connect Operator role in Connect has this permission. Sending an email requires the user that configures the connection to have permission to the content set to which you assign the email server profile. For more information about predefined roles in Connect, see User role requirements. For information about configuring custom roles, see Managing roles

    Note: If you delete an email server profile configuration that is referenced by a scheduled connection, future scheduled instances of that connection fail.
  • Configure a network egress allow list rule for the SMTP server.

  • You can use the Email (O365 & SMTP) destination to send data to an SMTP destination that is not accessible from the internet. To do so, make sure your environment meets the requirements listed at Configure sending data to an on-premises destination that is not accessible from the external internet.

  • You must have email addresses to send and receive email results.

  • Gather information about your mail server, including host, port, certificate, user name, password.

Note: Standard TCP ports for secure email using SMTP include 465 and 587. Tanium does not support sending data over TCP port 25 outbound.
Important: To use port 587 in an SMTP profile, Tanium might need to update the protocol to TCP. For assistance, Contact Tanium Support.

Configure sending data to an on-premises destination that is not accessible from the external internet

Note: You can use a satellite to send data to an SMTP server that is not accessible from the external internet. To use a satellite, specify the satellite in the email profile to use for the connection. For more information about creating an SMTP email profile in Connect, see Configure email server profile settings for SMTP.

Certain destinations support using a configured satellite to send data to an on-premises server that is not accessible from the external internet. Make sure that your environment meets the following requirements:

  • Tanium Client: 7.7.3.8176 or later

  • Tanium Direct Connect

    • Configure at least one satellite that can establish communications with the on-premises destination. For the best results, use a satellite with at least four processor cores and 16 GB of memory. Satellites with less memory might be sufficient for small data volumes. Satellite configuration requires the Direct Connect Satellite write permission. For more information, see Managing satellites.

  • Tanium Endpoint Configuration

    • Tanium Endpoint Configuration installs Client Extensions and other tools for Direct Connect on endpoints. Sending Tanium Cloud data using a configured satellite requires Core CX 2.15.1306 or later and DEC CX 2.10.1745 or later. For more information, see Client extensions.

  • To configure the connection destination, configure a custom role that includes the Direct Connect Satellite read and Client Stream write Direct Connect permissions. For more information, see Configure a custom role.

    Note: Assign the Sensor read permission for the Endpoint Configuration content set to users who need to configure satellites.
    • If a user has the Sensor read permission for the Endpoint Configuration content set, satellites that do not have the required versions of core-cx or dec-cx endpoint tools do not appear as options.

    • If a user does not have the Sensor read permission for the Endpoint Configuration content set, satellites that do not have the required versions of core-cx or dec-cx endpoint tools can still appear as options. If you select a satellite that does not have the required versions of the endpoint tools, an error appears when you try to save the connection.

    The Connect Operator system role contains the required permissions in addition to the Sensor read permission.

  • Ensure that each user is assigned the custom role, and has access to the computer group containing the satellite intended for sending data to an on-premises destination. For more information, see Manage computer group assignments for a user.

Note the following:

  • You can configure a bandwidth throttle to limit the bandwidth and the number of concurrent connections used to send data to satellites. For more information, see Managing bandwidth throttles.

  • You cannot configure a connection using a satellite until the satellite status updates to online. Satellites might take several minutes or more to update to online after configuration.

  • Connection sources that gather information from endpoints, such as the Saved Question source, must finish gathering information before the satellite connection is established.

  • The Retrieve Properties and Retrieve Columns buttons use the configured Connect Timeout advanced setting value. Because on-premises destinations might require more time to establish a connection, increase Connect Timeout to 60 seconds.

Specify general connection information

  1. From the Main menu, go to Modules > Connect > Overview. Go to the Connections section and click Create Connection.
  2. Enter a name and description for the connection.
  3. (Optional) In the General Information section, expand Advanced to configure the following settings:
    Log Level

    By default, Log Level is set to Information. To reduce the amount of logging, you can set Log Level to Warning, Error, or Fatal.

    Example Log Level setting
    Override Log Level

    If you are debugging the connection, select Override Log Level to set a Temporary Log Level (such as Trace or Debug) on this connection for a selected Number of Runs (up to 24). A scheduled or manual connection run, once started, counts towards the number of runs, regardless of the connection status. After the number of runs elapses, the logging for this connection returns to the Log Level you selected to prevent finer-grained logging from consuming additional resources for an indefinite number of runs.

    Minimum Pass Percentage

    Minimum percentage of the expected rows that must be processed for the connection to succeed.

    Memory Ceiling (GB)

    Maximum memory for the node process to run the connection. This defaults to 1 GB per connection, and cannot exceed the global maximum sum of memory for all running connections (by default, 8 GB). Increase this setting if a connection frequently exhibits out of memory errors while running.

    Note: If the sum of simultaneously scheduled connection Memory Ceiling values exceed the global Memory Ceiling, connections run until the global Memory Ceiling is reached, then any remaining connections enter a waiting queue if you select the Queue Connections configuration setting, or fail if you clear the Queue Connections configuration setting.

Configure the connection source

The connection source determines what data you are sending to the destination. This data is usually information from Tanium, such as a saved question, question log, client status, or event. The settings vary depending on which source you choose.

Figure 1. Connection source settings
Connection source settings
Note: After you create a connection, you cannot update the connection source type, only the source configuration. If you want to change the source type, create a new connection.

For more information about available connection sources, see Connection sources.

Configure the email results destination

Note: After you create a connection, you cannot update the connection destination type, only the destination configuration. If you want to change the destination, create a new connection.
  1. For Destination, select Email (O365 & SMTP).
  2. Provide a name for the destination. Options include:
    • Create a new destination: Specify a unique name to save the configuration information as a new destination. Select New and then enter a Destination Name

    • Copy an existing destination: Select New, and then click Copy Settings. Select a destination, click Apply, and update the Destination Name.

    • Reuse an existing destination: Select Existing, and then select a Destination Name.

      Note: Configure a unique destination per connection. If you edit the settings for a shared destination for one connection, any other connections that use the shared destination are affected, and connection runs might fail.
  3. Select an Email Server Profile from the drop-down list.
  4. Provide information about the email Subject, To Addresses, Cc Addresses, and Bcc Addresses.

    The Subject field supports variable substitution, as listed in Reference: Variables.

    Example Connect configuration for an email destination through Microsoft 365
  5. (Optional) Specify attachment settings.

    The Attachment Filename field supports variable substitution, as listed in Reference: Variables.

    Example attachment settings for an email destination through Microsoft 365
    • Attachment is selected by default. Enter up to 5000 characters of email Body text included with each email. Specify a file name and file extension in the Attachment Filename. The file extension does not need to match the format option you select in the Format section. Note the option that you select in the Format section does not add or change the file extension. Select a Filename Timestamp Format if you want to append a timestamp to the file name.

      Note: The Tanium Reporting source requires selecting Attachment.
    • You can compress the attachment into a zip or gzip file. If you select a compression method, the file extension for the compression method is automatically added to the end of the file name.

Configure filters

(Optional) In the Configure Output > Filters section, you can specify filters to modify the data that you are getting from your connection source before it is sent to the destination.

For more information about the types of filters you can configure, see Reference: Filtering options.

Format data for email

You can choose from any of the available formats for your email. The data is sent in an email attachment by default.

If you want to have the data in the body of the email instead of attaching a file to the email, edit the email destination settings to clear Attachment.

You can choose the columns that appear in the resulting email.

Note: If the data format supports row delimiter characters, update the characters to ensure that individual rows are sent in a format that the destination can parse. You can define one or more of \n (new line), \r (carriage return), and \t (tab).

In the Configure Output > Columns section, you can change the Destination Label of each column and Value Type to force the column to be a String, Numeric, or Date/Time value.

Figure 2. Columns section with Destination Label and Value Type fields
Columns section with Destination Label and Value Type fields

If you choose Numeric for the value, you can specify a default value that is used if the data cannot be coerced into a numeric value. You can specify any negative or positive number.

If you choose Date/Time for the value, specify the format that you want to use for the column. For more information about how to use a variable, see Time stamp variables.

For more information about column customizations, see Reference: Column customizations.

Schedule the connection

Connections can run at a highly configurable time interval, such as multiple times per hour, day, week, or month.

Important: Connections scheduled to run during a Tanium Cloud maintenance window might be interrupted or fail. Schedule your connections to run outside of the Tanium Cloud maintenance window.
Note: If you do not enable the schedule, the connection only runs when you manually run it, unless you configure an Event source. Connections with Event sources only run when a configured event is detected, and cannot be scheduled or manually run.

Use the Schedule section to update the schedule:

  • Select Enable schedule.

  • In the Schedule Type, select Basic to build a schedule with the provided controls.

  • To view or edit the cron expression directly, select Advanced - Define as a Cron Expression, and use the Advanced field to edit the cron expression.

Note: If a user that owns a scheduled connection is deleted, future scheduled instances of that connection do not run. For more information, see Issue: Scheduled connection owned by a deleted user no longer runs.

For more information about cron syntax, see Reference: Cron syntax for Connect.

Enable listening for an event

Connections with Event sources only run when a configured event is detected, and cannot be scheduled or manually run.

Use the Enablement section to send data when a configured event is detected:

  • Select Listen for this Event.

Save and verify connection

  1. After you enter the details for the connection, click Save.
    Tip: To save the connection and immediately run the connection, click Run and Save.

    If needed, resolve any errors or missing information. After the connection creates successfully, the connection details appear.

  2. To view details when the connection runs, click the Logs tab.
  3. To view an individual run log, expand the row table. For more information about how to resolve errors, see Troubleshooting.