Troubleshooting Direct Connect and Screen Sharing

Generate a support package

Collect information about the current state of the Direct Connect service to use for troubleshooting. The information is saved as a ZIP file that you can download with your browser. The ZIP file is also known as a support bundle.

  1. From the Main menu, go to Shared Services > Direct Connect and click Help help > Troubleshooting.
  2. Click Generate Support Package and then click Download Support Package to download the ZIP file to the local download directory.
  3. Contact Tanium Support to determine the best option to send the ZIP file. For more information, see Contact Tanium Support.

Change the logging level

The logging level determines how much detail Direct Connect records in its logs for events such as endpoint connection attempts. Select a level based on how much detail you need for troubleshooting. The level of detail from most to least is DEBUG, INFO, WARN, and ERROR.

Note: Changes to the logging level apply only to future events. The changes do not affect the data that is available in the support package for events that occurred before the changes.
  1. From the Main menu, go to Shared Services > Direct Connect and click Help help.
  2. Select the Troubleshooting tab and select the Log Level.

Troubleshoot endpoint connection issues

Connection process

Understanding how Tanium platform settings are involved in the endpoint connection process can help you troubleshoot connection issues. Each endpoint is configured to connect with a specific Tanium Server or Tanium Zone Server. An active-active deployment includes multiple Tanium Servers and Zone Servers. When you attempt a connection, Direct Connect iterates through the configured servers in the following order until a successful connection occurs:

  1. The server specified in the LastGoodServerName setting (if available)

  2. The last server used for a successful connection

  3. The server with the most successful connections

  4. The server specified in the ServerName setting (if configured)

  5. Any servers specified in the ServerNameList setting

For more information about the preceding settings, see Settings for connections to Tanium Core Platform Servers.

Troubleshoot connections

Perform the following steps if you cannot establish an endpoint connection.

Tip: To include more details in the logs that record Direct Connect events on an endpoint, see Change the logging level.
  1. Go to Administration > Actions > Action History and check the status of the action named Deploy Direct Connect - Open Session - <operating system> - <session ID>. If the page lists multiple Direct Connect actions, match an action with a particular connection attempt based on the Start Time value.
  2. Perform one of the following tasks based on whether the action ran on the endpoint:
    • Action ran but unsuccessfully: Check the <Tanium Client installation directory>/Logs/extensions0.txt log on the endpoint. Make sure that the endpoint can connect to the Module Server using the Fully Qualified Domain Name and Port that you configured on the Endpoint Connection tab in the Direct Connect settings.

    • Action did not run: Verify that the endpoint meets the following conditions:

      • Action group: Verify that the endpoint is a member of the Direct Connect action group. If the endpoint is not a member, update the action group to include a computer group to which the endpoint is assigned. For more information, see Targeting actions through action groups.

      • Direct Connect tools: Verify that the endpoint has the latest tools, as described in Verify endpoint tools.

    • Screen sharing action failed with status ActionCommandTimedOut and the endpoint user did not see a consent prompt: Application control software, such as AppLocker or Windows Defender Application Control (WDAC), might be blocking the ScreenMeet.Support.exe process. On the endpoint, check the Microsoft-Windows-AppLocker/EXE and DLL event log for event ID 8004 with an all-zero rule ID, which indicates that no application control rule matched the process. For more information about permitting ScreenMeet.Support.exe in an application control policy, see Application control policies.

Troubleshoot Zone Proxy connection issues

You install and configure the Tanium Direct Connect Zone Proxy if endpoints form Direct Connect connections to the Module Server through a Tanium Zone Server. If you cannot establish an endpoint connection after installing and configuring the Zone Proxy, check the Direct Connect Zone Proxy log for errors: <Tanium>/TaniumDirectConnectZoneProxy/logs/proxy.log. For more information, see Manage a Tanium™ Zone Proxy.

Screen sharing buttons unavailable

Screen sharing buttons and related functionality might not be available in Tanium Console while the system rotates ScreenMeet key information. By default, this action occurs once every 30 days. Wait up to 30 minutes for this action to complete and then try accessing screen sharing functionality. For more information about next steps if you still cannot access screen sharing functionality, contact Tanium Support.

Poor Connection Quality message when attempting to join a screen sharing session

When attempting to join a screen sharing session, a user accessing Screen Sharing using Microsoft Edge receives this message: Poor connection quality. Attempting to reduce video bitrate... Activate Low Performance Mode. This message can occur if the Microsoft Edge setting Control if audio and video play automatically on sites is set to Blocked. To resolve the issue, set this value to Limit (default setting) or Allow. For more information about this setting, see Microsoft: How to manage autoplay in Microsoft Edge.

Verify endpoint tools

Perform the following steps to diagnose issues such as a Direct Connect feature not working on an endpoint or incorrect data in the Direct Connect workbench. For example, you might see the following message when attempting to start an endpoint connection:

Warning  The Direct Endpoint Connection tools are not installed

  1. Verify that endpoints have the latest Direct Connect tools installed by using any Tanium Console or Interact question field to issue the following question.
    PYTHON
    Get Endpoint Configuration - Tools Status contains Direct Connect from all machines with Endpoint Configuration - Tools Status contains Direct Connect

    To view the tools version on a single endpoint, add a filter to the from clause of the question that identifies the endpoint. For example, if you know the computer name, you can issue the following question.

    PYTHON
    Get Endpoint Configuration - Tools Status contains Direct Connect from all machines with ( Endpoint Configuration - Tools Status contains Direct Connect and Computer Name equals <computer name>)

    The Installed Version is lower than the Targeted Version on endpoints that do not have the latest tools.

  2. If the latest tools are not installed, see Identify and resolve issues with endpoint tools or Client extensions.

Verify the configuration version

On the Direct Connect Overview page, the following warning means that the Direct Connect configuration has changed from what was last installed on the endpoint:

Warning  The most recent version of the configuration is not installed for endpoints

The endpoint might not be able to connect depending on what changed. This condition usually resolves automatically if you wait for Tanium Endpoint Configuration to deploy the latest configuration to endpoints. Perform the following steps to diagnose the condition if it persists:

  1. From the Main menu, go to Shared Services > Endpoint Configuration > Configurations.
  2. Expand Expand the Filters and enter dec as the Domain to show only Direct Connect configurations.
  3. Record the revision number in the Description column. For example, the value might be Direct Connect config revision 15.
  4. View the Direct Connect revision on endpoints by using any Tanium Console or Interact question field to issue the following question.
    PYTHON
    Direct Connect - Connection Configuration and "Client Configuration and Support - Is Container" from all machines

    To view the revision on a single endpoint, add a filter to the from clause of the question that identifies the endpoint. For example, if you know the computer name, you can issue the following question.

    PYTHON
    Direct Connect - Connection Configuration and "Client Configuration and Support - Is Container" from all machines with Computer Name equals <computer name>
  5. If the endpoint does not have the latest Direct Connect configuration revision, verify that the endpoint has the latest manifest and update the manifest if necessary. For more information, see Verify and manually update the Endpoint Configuration manifest.

Remove Direct Connect tools from endpoints

You can deploy an action to remove Direct Connect tools from an endpoint or computer group. Separate actions are available for Windows and non-Windows endpoints.

  1. In Interact, target the endpoints from which you want to remove the tools. For example, ask a question that targets a specific operating system:Get Endpoint Configuration - Tools Status from all machines with Is Windows equals true
  2. In the results, select the row for Direct Connect, drill down as necessary, and select the targets from which you want to remove Direct Connect tools. For more information, see Drill down into results.
  3. Click Deploy Action.
  4. For the Deployment Package, select Endpoint Configuration - Uninstall Tool [Windows] or Endpoint Configuration - Uninstall Tool [Non-Windows], depending on the endpoints you are targeting.
  5. For Tool Name, select Direct Connect.
  6. (Optional) By default, after the tools are removed they cannot be reinstalled. To allow tools to be automatically reinstalled, clear the selection for Block reinstallation. Re-installation occurs almost immediately.
    Note:

    If reinstallation is blocked, you must unblock it manually:

    • To allow Direct Connect to reinstall tools, deploy the Endpoint Configuration - Unblock Tool [Windows] or Endpoint Configuration - Unblock Tool [Non-Windows] package (depending on the targeted endpoints).

    • If you reinstall tools manually, select Unblock Tool when you deploy the Endpoint Configuration - Reinstall Tool [Windows] or Endpoint Configuration - Reinstall Tool [Non-Windows] package.

  7. (Optional) To remove all Direct Connect databases and logs from the endpoints, clear the selection for Soft uninstall.
    CAUTION: When you perform a hard uninstallation of some tools, the uninstallation also removes data that is associated with the tool from the endpoint. This data might include important historical or environmental data. If data that you want to keep is associated with the tool, make sure you perform only a soft uninstallation of the tool.
  8. (Optional) To also remove any tools that were dependencies of the Direct Connect tools that are not dependencies for tools from other solutions, select Remove unreferenced dependencies.
  9. (Optional) In the Deployment Schedule section, configure a schedule for the action.
    Tip: If some target endpoints might be offline when you initially deploy the action, select Recurring Deployment and set a reissue interval.
  10. Click Show preview to continue.
  11. A results grid appears at the bottom of the page showing you the targeted endpoints for your action. If you are satisfied with the results, click Deploy Action.
    Note: If you have enabled Endpoint Configuration approval, tool removal must be approved in Endpoint Configuration before tools are removed from endpoints.

Uninstall Direct Connect

CAUTION: Direct Connect is a shared service that is used by several Tanium solutions. If Direct Connect is in use by another Tanium solution, uninstalling Direct Connect or removing the tools from endpoints could have unintended consequences. Contact support@tanium.com to determine whether uninstalling Direct Connect is advisable in your environment.

Uninstall the Direct Connect Zone Proxy

The steps to remove the Tanium Direct Connect Zone Proxy depend on your Tanium infrastructure:

  • Windows: Sign in to the Tanium Zone Server as a user with Local Administrator rights, open Control Panel > Programs > Programs and Features, select the Tanium Direct Connect Zone Proxy, and click Uninstall.

  • TanOS: See Remove the Direct Connect Zone Proxy.