Reference: Common Recorder health check issues
Review common Recorder health check issues and possible solutions.
Failed to connect to ETW File Provider.
- Cause
-
This health check displays when a connection to the ETW File Provider cannot be established.*
- Solution
-
Ensure that the Tanium Client is running with appropriate credentials. Disable/Enable the recorder (Restart -m process). Test removing and reinstalling tools.
*=The recorder was unable to connect to one or more ETW providers. Such connection issues often resolve themselves and a rare intermittent message of this type is not a cause for alarm. However, if you notice these errors persisting you will need to determine what is causing the issue. This can be caused by AV not being excluded properly and interfering with the recorder, by system CPU or RAM being exhausted at the time the recorder attempts to connect, and having so many other things subscribing to ETW, that there are no more connections for Tanium to utilize. Attempt to find OS/Hardware/Application similarities across any endpoints persistently showing these errors.
Failed to connect to ETW DNS Provider.
- Cause
-
This health check displays when a connection to the ETW DNS Provider cannot be established.*
- Solution
-
Ensure that the Tanium Client is running with appropriate credentials. Disable/Enable the recorder (Restart -m process). Test removing and reinstalling tools.
*=The recorder was unable to connect to one or more ETW providers. Such connection issues often resolve themselves and a rare intermittent message of this type is not a cause for alarm. However, if you notice these errors persisting you will need to determine what is causing the issue. This can be caused by AV not being excluded properly and interfering with the recorder, by system CPU or RAM being exhausted at the time the recorder attempts to connect, and having so many other things subscribing to ETW, that there are no more connections for Tanium to utilize. Attempt to find OS/Hardware/Application similarities across any endpoints persistently showing these errors.
Unable to determine kernel audit subsystem (kauditd) status from netlink.
- Cause
-
This health check displays when the recorder is unable to determine kernel audit subsystem (kauditd) status from netlink.
- Solution
-
If the netlink socket is in unicast mode, only one consumer (TaniumRecorder, Auditd etc.) can consume events at a time. Investigate using multicast mode to allow interoperability with other products and auditd.
Fatal error loading subscriptions: waiting for netlink socket to become available. Not getting events.
- Cause
-
This error displays when a kernel does not support multicast netlink. The netlink socket (the interface between kaudit and auditd) is in unicast mode and another consumer is consuming events.
- Solution
-
If the netlink socket is in unicast mode, only one consumer can consume events at a time (TaniumRecoder, Auditd etc.) Investigate using multicast mode to allow interoperability with other products and auditd.
Failed to configure BPF event providers.
- Cause
-
There are multiple potential causes for this error to display.
- Solution
-
Review the output of the Recorder - Is BPF Supported Details sensor. For more information see Troubleshooting the Client Recorder Extension.
Review \recorder\sensor-data\result.txt
Investigate if selinux is in "Permissive" mode.
Investigate selinux policies.
Investigate extensions0.txt - are other health items listed such as raw logging or rules failing to load?
Subscription has breached high threshold: <subscription name>.
- Cause
-
This health check displays when the number of pending journal files is greater than or equal to the high threshold (default 80% of max pending files).
- Solution
-
This health check is displayed when the receiving end or recorder data is at risk of losing data. For example, it is possible that the recorder has provided a signal to the Detect engine that Detect won’t see. Review subscription logs for all services that are using recorder data. Ensure that intel is up to date. No action is required on the recorder end to address this error. Ensure that systems meet the minimum requirements. Action to mitigate this health check may be required on the consumer end. For example, a signal that is returning many matches that result in alerts.