Reference: Common health check issues
Review common Client Index Extension health check issues and possible solutions.
Exception trying to start scan. Check extensions log.
- Cause
-
This health check appears whenClient Index Extension cannot start scanning. When this health check displays, it is not possible to receive data from Client Index Extension. This health check is cleared on client reset, after 4 hours.
- Modules where this health check occurs
-
This health check can occur in Integrity Monitor, Reveal, and Threat Response.
- Solution
-
To troubleshoot this health check, search the extensions log for "exception trying to start scan" to identify the cause of the error. To contact Tanium Support for help, send an email to support@tanium.com.
Scan completion took longer than configured scan interval. Maybe under spec or subscription misconfigured?
- Cause
-
This health check appears when an Index scan exceeds the configured scan interval.
- Modules where this health check occurs
-
This health check can occur in Integrity Monitor, Reveal, and Threat Response.
- Solution
-
Ensure that all endpoints managed using Tanium Client meet the system requirements for the Client Index Extension and that the subscription is configured properly. Add exclusions in Index, change scan frequency to give more time to scan, or increase the amount of CPU allocated to client extensions. An upgrade to Tanium Client Management version 1.10 is recommended.
For Integrity Monitor: Select to increase the scan frequency in the monitor and edit the watched path (for example, C:/) and select and add exclusions via regex.
For Reveal: Select to increase the scan frequency.
For Threat Response: Select to increase the scan frequency,
Not all High Priority paths were successfully registered with recorder.
- Cause
-
This health check appears when the recorder has not received the configuration of what Index should scan.
- Modules where this health check occurs
-
This health check can occur in Threat Response.
- Solution
-
This health check can occur when there is an error with Recorder, or one or more configuration issues. This health check can indicate a benign issue or can be indicative of a complete error. Refer to the troubleshooting documentation for Threat Response to gather logs and contact Tanium Support for help, To contact Tanium Support for help, send an email to support@tanium.com.
Subscription has dropped journals.
- Cause
-
This health check appears when Index is unable to send file change notifications to Integrity Monitor, because Integrity Monitor is not processing events. This health check can occur any time Index is pushing a file change notification to Integrity Monitor.
- Modules where this health check occurs
-
This health check can occur in Integrity Monitor.
- Solution
-
Investigate the health of IMCX. This could indicate that the recipient CX is not responding and that data is not being cleared. To contact Tanium Support for help, send an email to support@tanium.com.
Not executing scans due to disk space health check.
- Cause
-
This health check appears when Index is no longer indexing because the amount of free disk space is below the critical threshold.
- Modules where this health check occurs
-
This health check can occur in Integrity Monitor, Reveal, and Threat Response.
- Solution
-
For information about the disk space thresholds, the Client Extensions that use them, and how to change the values, see Managing client disk space thresholds.
Dropped high priority path events from recorder.
- Cause
-
This health check appears when Index cannot process events from recorder quickly enough, and has ignored some of those events.
- Modules where this health check occurs
-
This health check can occur in Integrity Monitor and Threat Response.
- Solution
-
The endpoint managed using Tanium Client is overwhelmed and does not have enough resources to catch and process all the events, or the watchlist needs to be tuned to lower the volume of events coming in.