Configuring Service Graph Connector for Tanium Atlas Endpoints

Configure Service Graph Connector for Tanium Atlas Endpoints to pull hardware, software, and usage data from Tanium Gateway to ServiceNow. Complete the steps in this topic after you have reviewed the Service Graph Connector for Tanium Atlas Endpoints requirements and created an API token.

Install Service Graph Connector for Tanium Atlas Endpoints

On your ServiceNow instance, install the Service Graph Connector for Tanium Atlas Endpoints plugin.

  1. Sign in to ServiceNow.

    In the filter navigator, enter Plugins. Click System Definition > Plugins.

    Figure 1. Setting up Service Now Service
    Setting up ServiceNow Service
  2. From the Application Manager page, find and then click Service Graph Connector for Tanium Atlas Endpoints.
  3. Click Install.
  4. Review the installation details, ensure Install now is selected, and then click Install.
    Note: Installing the Service Graph Connector for Tanium Atlas Endpoints plugin can take longer than 30 minutes.

(On-premises Tanium environments only) Set up a MID Server

If your Tanium environment is hosted on-premises, you must install and configure a ServiceNow MID Server to facilitate communication between Tanium and ServiceNow. A MID Server is not required for cloud-based Tanium environments.

For the steps to prepare for, install, and configure a MID Server, refer to the ServiceNow documentation.

Configure Service Graph Connector for Tanium Atlas Endpoints

Use the SGC Central playbook in the ServiceNow CMDB Workspace or Service Graph Workspace to configure the connection between ServiceNow and Tanium.

  1. Sign in to ServiceNow.
  2. Go to Workspaces > CMDB Workspace > SGC Central.
  3. From the Overview page, click Create connection.
  4. Select the Tanium Atlas Endpoints connector type and then click Create connection.
  5. If this is the first time you set up a connection, complete the Prerequisites steps, which includes updating access to the sys_data_source table and clearing the cache.
    Note: Ensure the script that clears the cache completes before moving to the next step.
  6. In the Configure and test connection step, enter the connection details and test the connection:
    1. Specify the following fields:
      Table 1. Service Graph Connector for Tanium Atlas Endpoints connection settings

      Field

      Description

      Connection name

      A name to identify the Tanium connection.

      Host name

      The base URL or IP address of the Tanium instance. For Tanium Server instances, this value is the URL of the Tanium Server. For Tanium Cloud instances, this value is the API access point for your instance, in the format <customerURL>-api.cloud.tanium.com.

      Token

      The Tanium API token that you created in Create an API token. The token value includes the token- prefix.

      Use MID Server

      Select this option if your Tanium instance is hosted on-premises. Use of a MID Server is optional for Tanium Cloud instances.

      MID selection

      The name of the MID Server. This field appears only when Use MID Server is selected.

    2. Click Create and test connection.

      Ensure the connection is successfully verified before you continue.

      Note: A successful HTTP status code of 200 does not always confirm that permissions are correct. If the import set later returns 0 rows, verify that all required Tanium roles are assigned to the service account or persona. For more information, see Tanium role requirements.
    3. Click Continue.
  7. (Optional) Configure additional sensors.

    The connector includes a default set of sensors. You can configure additional sensors to import extra endpoint attributes. To skip this step, click Skip.

    1. Click Fetch sensors to populate the SG-Tanium-Endpoints Sensors table with available sensors.
    2. For sensors you want to import, set the value of the Ingest column to true.
    3. Set the Type field for each sensor that you want to import:
      • Single line: Use for sensors that return simple, flat data.

      • Multiline: Use for sensors that return complex, nested data structures.

      Note: The normalized sensor name in the SG-Tanium-Endpoints Sensors table is derived from the sensor name by removing spaces and replacing special characters with underscores. Use this normalized name when you configure Robust Transform Engine (RTE) mappings or reference the sensor by its JSON key.
    4. Click Mark as Complete.
  8. Configure the import schedule:
    Warning: The Scheduled Data Imports list in ServiceNow might include two sets of imports. One set contains the template imports associated with the parent connection alias. The other set is generated automatically for the child alias of each connection that you configure. Activate only the import schedules that SGC Central lists. Keep only one set of import schedules active for each connected Tanium environment.
    1. In the row of a import schedule that you want to use for your connection, click the name to edit the record.

      The Configure import schedule dialog opens.

    2. Set Active to true.
    3. Enter the run schedule details.
    4. Click Save.
    5. Configure additional import schedules as needed. When finished, click Continue.
      Note: The option to continue is enabled when a valid import schedule is configured.

After the setup completes, the Confirm connection setup page opens. Click View all connections to review the connection details. You can manage connections from the SGC Central view of the CMDB Workspace.

Verify endpoints were successfully imported

After you configure and run the connection, verify that Tanium endpoint data appears in ServiceNow.

  1. Sign in to ServiceNow. In the filter navigator, enter Computer. Click Configuration > Base Items > Computers.
  2. If the Discovery source column does not appear in the table, click Personalized List cog, move Discovery source to the Selected list and then click OK.
  3. Verify that you can see entries with a Discovery source of SG-TaniumEndpoint. These records were added or last updated by Service Graph Connector for Tanium Atlas Endpoints.