Setup for this application involves three key steps:
Configure the ServiceNow app for Tanium.
Configure the Integrity Monitor Watchlist Saved Question.
This step is required to collect watchlist event data on a schedule throughout the day (configurable)
Configure the Connect Job.
This step uses the saved question as a source of data to export to the destination for the Tanium FIM Integration.
ServiceNow App Setup
Download the Tanium File Integrity Monitoring integration from the ServiceNow Store.
Select Install.
An Application installation window opens. Click Install.
Allow the setup to complete.
Select Close.
Note: This application installs some custom tables. Check with your ServiceNow representative to determine if there are any additional associated costs.
Saved Question
Configure the Integrity Monitor Watchlist Saved Question.
Sign in to Tanium Console.
Go to the Tanium Home page or Interact Overview page.
To create a new question, click Build Question.
Click + Add below Get the following data to create the get statement.
Add the following sensors:
Computer Name
Computer Serial Number
Integrity Monitor – Monitor Events with the following parameters:
(You may leave the parameters as their default values, or configure them to suit your needs, but please work with Tanium Global Support to make sure you’re not potentially missing any critical events)
Row Limit: 10
Monitor ID: 0
Timestamp minute resolution: 15
Exclude label list: (un-checked)
CSV Label Search: (leave blank)
Add the following filters (in the “from computers with” section):
Add filter row and select the Sensor: Computer Name, and set the filter to is not equal to null.
Add filter row and select the Sensor: Computer Serial Number, and set the filter to is not equal to null.
Add filter row and select the Sensor: Integrity Monitor – Monitor Events, and Set the filter to: matches ^\d{4}.*
Figure 1. Saved Question 1
When finished, after making sure that you’ve clicked Apply on each line, click Ask Question.
On the live results page, confirm you get data.
Click Save above the question field.
Configure the following settings:
Name: Tanium FIM Integration.
Content Set: Interact.
Reissue: Select Reissue this question every and specify 4 hours or your desired interval (4hrs or 8hrs).
Click Save.
Connect Job
Create a Tanium Connect job to retrieve data from the saved question and schedule an export to ServiceNow and the Tanium FIM Integration API in ServiceNow.
From the Main menu, go to Modules > Connect > Connections, and click Create Connection.
Under General Information set the following values:
Set the Name field to Tanium FIM Integration
Optionally, enter a meaningful Description which indicates that this integration is for the ServiceNow FIM/Unauthorized Change Monitoring application.
Expand the Advanced section, and set the following values:
Log level: Warning
Minimum Pass Percentage: 0
Memory Ceiling: 1
(work with Tanium Global Support to adjust this value if needed for large exports)
In Configuration section, select the following settings:
Source: Saved Question
Saved Question Name: <select the saved question you created earlier>
Computer Group: All Computers (or select the group that makes sense)
Check the following checkboxes:
Flatten Results
Hide Errors
Hide No results
Include Recent Answers
Expand the Advanced sub-section under the Configuration section, and set the below values
Note: We recommend contacting Global Support if you need help configuring these settings to suit your environment.
Answer Complete Percent: 0
Timeout: 10
Batch Size: 1000
Batch Size Unit: Records
In the Destination section, configure the following settings:
Destination: HTTP
Make sure that New is selected and give the new destination a meaningful Destination Name such as ServiceNow FIM Integration.