Create a sensor to pull CVE status

The Custom Comply - CVE Findings - Resolution Complete sensor is a custom sensor that collects CVE resolution status data from endpoints. This includes the resolution date, number of days an endpoint was exposed, the current vulnerability status, and more. Tanium does not include this sensor by default, so you must create the sensor manually. Tanium Exposure Management for ServiceNow uses this sensor together with Comply - CVE Investigation Details to populate vulnerability records in ServiceNow with current findings from Tanium Comply.

  1. In Tanium Console, go to Administration > Content > Sensors, and then click New Sensor.
  2. Configure the sensor with the following settings:
    1. Details section:
      • Name: Custom Comply - CVE Findings - Resolution Complete

      • Description: Returns the resolution date, days open and current status for all observed vulnerabilities that the endpoint has been vulnerable to within the last X days.

      • Content Set: Comply Reporting

    2. Settings section:
      • Category: Compliance

      • Result Type: Text

      • Max Sensor Age: 15 Minutes

      • Max String Age: Enable for 7 days

      • Max Strings: Deselected (disabled)

      • Ignore case in result values: Selected (enabled)

      • Hide this sensor from sensor lists and parse results: Deselected (disabled)

      • Split into multiple columns: Selected (enabled)

      • Use Delimiter: |

    3. Column Name table (this table appears after you select Split into multiple columns):
      • 1

        • Column Name: CVE

        • Result Type: Text

      • 2

        • Column Name: First Seen

        • Result Type: Date/Time (RFC822)

      • 3

        • Column Name: Last Seen

        • Result Type: Date/Time (RFC822)

      • 4

        • Column Name: Status

        • Result Type: Text

      • 5

        • Column Name: Days Open

        • Result Type: Numeric

      • 6

        • Column Name: Resolution - Date

        • Result Type: Date/Time (RFC822)

      • 7

        • Column Name: Type

        • Result Type: Text

    4. In the Parameters section, click Add Parameter, select Numeric, and then specify the following information:
      • Key: days

      • Label: Exclude CVEs not seen in X days

      • Select the following Options and specify the included values:

        • Provide Help Text: Exclude CVEs not seen in X days

        • Provide Default Value: 45

        • Provide Minimum Value: 1

        • Provide Maximum Value: 180

    5. In the Implementation section, add the scripts found at Vulnerability Management Comply Orchestration with Tanium – Appendix (Sign-in Required), or contact Tanium Support for the supported operating system scripts. You must add the script for each operating system to save the sensor. For each script, ensure you select the correct Query Type that is noted with each script.
    6. Click Save.