Troubleshooting Interact

View and copy the Local Error Log

Tanium Interact maintains an error log on the local host computer for your web browser. It includes details on the last 100 errors that were returned to the Interact in response to actions that you performed through the browser. For example, the log records errors that are associated with attempting to save a configuration or import a content file. Interact maintains a separate log for each browser that you use.

  1. In the Interact header, hover over the user icon User and select Local Error Log.
  2. (Optional) Expand Expand a log entry and Copy Copy the log details to the clipboard.
  3. (Optional) Click Clear Log if you want to remove all the log entries. For example, you might want to remove the entries after you finish resolving the associated issues.

Troubleshoot question runtimes

If Tanium Clients answer a question slower than expected, the question might use sensors that take a long time to run. When you enter text in the Question Ask a Question field, Interact shows the average runtimes of sensors that you select for questions. If necessary, you can customize the thresholds that determine which icon appears for a specific runtime, as described under Assessing question impacts on endpoints through sensor runtime indicators.

On the Question Results page, you might initially see the answer [current result unavailable]from endpoints that take longer than usual to evaluate a question sensor. For more information, see Current result unavailable.

Complex regular expressions might increase the time that Clients take to answer a question. For more information, see Reference: Advanced question syntax in Interact.

Troubleshoot question results issues

If the Question Results page shows errors, unavailable results, or unexpected results, review the following issues and remediation tasks.

Note: The Tanium Console user preferences control, on a per-user basis, whether the Question Results page shows error results. For more information, see Customizing Console and Interact.
Table 1. Issues and remediation for question results

Issue

Remediation

No results

The Question Results grid shows [no results] from a Tanium Client if:

  • The sensor returns no value.

  • The Client does not have a value that matches the sensor filter. This occurs if you apply a filter to the get clause and not the from clause. For example, if the question is Get Computer Name starts with tan from all machines, all endpoints return answers and all endpoints that do not start with tan in their computer name return [no results].

    Note: Add the filter in the from clause. For example, Get Computer Name from all machines with Computer Name starts with tan does not return unexpected [no results] rows.

Current result unavailable

If an endpoint takes longer than usual to evaluate a sensor, it might initially supply the answer [current result unavailable] to the answer message that it passes along the linear chain and ultimately to the Tanium Server. However, the sensor process continues on the endpoint after supplying that initial answer and, upon completing the process, the endpoint sends its updated answer. The Server then updates the Question Results grid.

Results currently unavailable

The Question Results grid displays the [results currently unavailable] message to indicate that the Tanium Server cannot correctly parse an answer. Parsing errors can result from various conditions, such as the excessive growth of answer strings. Contact Tanium Support if you observe this message.

Too many results

The Question Results grid displays [too many results] to indicate that more results are available, but the Tanium Clients will not return the additional results. The Tanium Server has certain checks to limit the network and memory impact of questions. Because of how the Server generates these messages, you cannot drill down on this response. Try the following solutions to avoid this message:

  • Use sensors that are more focused.

  • Target only a certain endpoint or computer group to limit the unique number of strings for each answer.

  • Use a non-counting question instead of a counting question. For more information, see Counting and non-counting questions.

TSE-Error

Messages that begin with [TSE-Error indicate a Tanium Client is in a state that prevents it from answering the question. Common reasons include:

  • Unstable operating system (OS)

  • Configuration issues

  • Lack of memory

  • Sensor cannot execute the script

  • Antivirus software blocks:

    For more information about security exclusions to define across Tanium, see Reference: Endpoint security exclusions. For Windows-based Tanium Core Platform deployments, see Tanium Core Platform Server security exclusions.

  • Corrupted Windows Management Instrumentation (WMI) repositories

  • Sensor quarantines: The Question Results page displays TSE-Error: The sensor is quarantined if the question uses quarantined sensors. You can remove those sensors from quarantine if appropriate. For more information, see Manage sensor quarantines.

  • Issues related to the roles that are assigned to your user account. For more information, see Troubleshoot RBAC issues.

  • Issues related to the computer groups that are assigned to your user account. For more information, see Results missing from certain endpoints.

Results missing from certain endpoints

You can see question results only from endpoints in computer groups that are assigned to the user account or persona that you use to issue questions. If certain endpoints to do return results, troubleshoot computer group assignments and configurations:

  • Assignments: Verify that the appropriate computer groups are assigned. If your user account inherits computer group assignments, you might have to assign a different user group:

  • Configurations: View the computer group configurations to ensure that their membership Expression is correct. Note that you cannot edit the membership of a computer group. If the membership does not include the correct endpoints, you must create and assign a new computer group.

Tanium Client communication issues

View the status of Client connections and, if necessary, correct them. For more information, see Check the Client status.

Troubleshoot action deployment issues

To ensure actions deploy as expected and to troubleshoot deployment issues, see the task for the action type:

Troubleshoot TDS issues

Monitor resource usage for sensor results collection

Tanium Data Service (TDS) collects and stores the results of all sensors that are registered for collection so that users can see those results for endpoints that are offline at the moment the users issue questions. Sensor collection consumes resources such as network bandwidth, disk space on the Tanium Server, and processing on endpoints. Resource consumption increases with the cardinality of sensors. For more information, see Resource consumption for registered sensors. Interact provides charts that enable you to visualize resource usage metrics related to results collection.

Note: For more information and procedures related to sensor results collection, see Managing sensor results collection through TDS.
  1. From the Main menu, go to Modules > Interact > Overview and click Info Info> Metrics .

  2. Review the following charts:

    • Harvest Metrics: These charts display metrics related to the number of database rows that are processed when question results are collected for registered sensors.

    • Data Service Sensor Metrics: Use these charts to determine whether specific sensors are generating result strings that consume too much storage.

    • Data Service Database Metrics: These charts provide indicators on the disk space usage for TDS. The Database Key Size and Database Value Size charts show usage in bytes.

    • Data Service Resource Consumption Metrics: Use these charts to determine the resource usage for TDS.

Resolve TDS resource consumption issues

If you determine that sensor collection consumes too many resources, consider the following solutions:

Review TDS logs and question history

To troubleshoot other sensor collection issues, see:

  • TDS logs: These logs indicate when the Tanium Server issued each question to collect results, the question ID, and information about each sensor in the question. To access the logs, see:

  • Question history: From the Main menu, go to Administration > Content > Question History and use the question ID (Harvesting qid) from the TDS logs to find specific questions that the Tanium Server issued to collect sensor results. For more information, see Question history.

Collect TDS logs

To send information to Tanium Support for troubleshooting TDS, perform the following steps to collect logs and other relevant information. The information is saved as a ZIP file that you can download through your browser. The ZIP file is also known as a support bundle.

  1. From the Main menu, go to Modules > Interact > Overview and click Help Help > Troubleshooting.
  2. Click Download Support Package. A tanium-interact-support-<date-time>.zip file downloads to the local download directory.
  3. Attach the ZIP file to your Tanium Support case form or send it to Tanium Support. For more information, see Contact Tanium Support.

Uninstall Interact

If you need to uninstall Interact, perform the following steps.

Important: If you uninstall Interact, and no users, personas, or user groups are assigned to the Feed User role before uninstalling Interact, you lose the ability to access Tanium™ Feed. To regain access to Feed, either reinstall Interact, or assign users, personas, or user groups to the Feed User role.
  1. Sign in to Tanium Console as a user with the Administrator role.

  2. From the Main menu, select Administration > Configuration > Solutions.

  3. In the Interact tile, click Uninstall Uninstall.

To reinstall Interact, see Installing Interact.