Configuring SMTP email destinations

Important: The email (SMTP) destination described in this chapter is deprecated and will be removed in a future release. The destination appears in Connect as Email (Legacy SMTP). Support for SMTP servers continues through the Email (O365 & SMTP) destination and email server profiles. For more information, see Configuring email destinations and Configure email server profile settings for SMTP.

You can send information from a connection source to a set of email addresses using SMTP servers. You can either include the results in the email body, or create an attachment.

Prerequisites

  • Email addresses for sending and receiving email results.

  • Information about your mail server, including host, port, user name, password, and authentication information.

Note: Standard TCP ports for secure email using SMTP include 465 and 587. Do not send unencrypted data over TCP port 25 outbound.

Specify general connection information

  1. From the Main menu, go to Modules > Connect > Overview. Go to the Connections section and click Create Connection.
  2. Enter a name and description for the connection.
  3. (Optional) In the General Information section, expand Advanced to configure the following settings:
    Log Level

    By default, Log Level is set to Information. To reduce the amount of logging, you can set Log Level to Warning, Error, or Fatal.

    Example Log Level setting
    Override Log Level

    If you are debugging the connection, select Override Log Level to set a Temporary Log Level (such as Trace or Debug) on this connection for a selected Number of Runs (up to 24). A scheduled or manual connection run, once started, counts towards the number of runs, regardless of the connection status. After the number of runs elapses, the logging for this connection returns to the Log Level you selected to prevent finer-grained logging from consuming additional resources for an indefinite number of runs.

    Minimum Pass Percentage

    Minimum percentage of the expected rows that must be processed for the connection to succeed.

    Memory Ceiling (GB)

    Maximum memory for the node process to run the connection. This defaults to 1 GB per connection, and cannot exceed the global maximum sum of memory for all running connections (by default, 8 GB). Increase this setting if a connection frequently exhibits out of memory errors while running.

    Note: If the sum of simultaneously scheduled connection Memory Ceiling values exceed the global Memory Ceiling, connections run until the global Memory Ceiling is reached, then any remaining connections enter a waiting queue if you select the Queue Connections configuration setting, or fail if you clear the Queue Connections configuration setting.

Configure the connection source

The connection source determines what data you are sending to the destination. This data is usually information from Tanium, such as a saved question, question log, client status, or event. The settings vary depending on which source you choose.

For more information about available connection sources, see Connection sources.

Figure 1. Connection source settings
Connection source settings
Note:

If a Tanium solution or source shows Critical state-critical, the installed solution does not meet the minimum required version for proper compatibility and functionality. Upgrade the solution to the minimum required version or later.

Note: After you create a connection, you cannot update the connection source type, only the source configuration. If you want to change the source type, create a new connection.

Configure the Email (SMTP) results destination

Note: After you create a connection, you cannot update the connection destination type, only the destination configuration. If you want to change the destination, create a new connection.
  1. In the Email section for the Email (SMTP) destination, provide a name for the destination.
    • Create a new destination: Specify a unique name to save the configuration information as a new destination. Select New and then enter a Destination Name.

    • Copy an existing destination: Select New, and then click Copy Settings. Select a destination, click Apply, and update the Destination Name.

    • Reuse an existing destination: Select Existing, and then select a Destination Name.

      Note: Configure a unique destination per connection. If you edit the settings for a shared destination for one connection, any other connections that use the shared destination are affected, and connection runs might fail.
  2. In the Email section, provide information about the email Subject, From Address, and To Address sections.

    Some fields also support variable substitution, as listed in Reference: Variables.

    Example Connect configuration for an SMTP email destination
  3. Specify information about the mail server in the Mail Configuration section:
    Example mail configuration for an SMTP email destination
    • Provide the host name, port, user name, and password.

      Important: Google Workspace ends support for logins with a Google username and password on September 30, 2024. Update your connections to Google Workspace email destinations with an app password before this date. For more information about how to use an app password, see Gmail Help: Sign in with app passwords.
    • Select Secure if the connection with the SMTP server is authenticated and uses TLS encryption.

      Note: If you do not select Secure, authentication information is encrypted at rest, but passed unencrypted to the destination.
    • Specify a Timeout value for sending the message. The default is 0, which means that there is no timeout. A recommended timeout value is 10 seconds.

  4. (Optional) Specify advanced settings.

    Some fields also support variable substitution, as listed in Reference: Variables.

    Example advanced settings for an SMTP email destination
    • You can configure CC and BCC addresses for the email and specify the settings for the email attachment.

    • Attachment is selected by default. Specify a file name and file extension in the Attachment File Name. The file extension does not need to match the format option you select in the Format section. Note the option that you select in the Format section does not add or change the file extension.

    • You can compress the attachment into a zip or gzip file. If you select a compression method, the file extension for the compression method is automatically added to the end of the file name.

    • Under Connection Runs Without Results, select Send Email to send an email if the connection run generates no results. Enter a message in the Email Body field to include in the email body.

Configure filters

(Optional) In the Configure Output > Filters section, you can specify filters to modify the data that you are getting from your connection source before it is sent to the destination.

For more information about the types of filters you can configure, see Reference: Filtering options.

Format data for email

You can choose from any of the available formats for your email. The data is sent in the body of the email by default.

If you want to attach a file to the email instead of having the data in the body of the email, edit the Advanced settings for the Email destination and select Attachment. Specify a file name and whether the file should be compressed.

The data format for email destinations is HTML by default. You can choose the columns that appear in the resulting email.

Note: If the data format supports row delimiter characters, update the characters to ensure that individual rows are sent in a format that the destination can parse. You can define one or more of \n (new line), \r (carriage return), and \t (tab).

In the Configure Output > Columns section, you can change the Destination Label of each column and Value Type to force the column to be a String, Numeric, or Date/Time value.

Figure 2. Columns section with Destination Label and Value Type fields
Columns section with Destination Label and Value Type fields

If you choose Numeric for the value, you can specify a default value that is used if the data cannot be coerced into a numeric value. You can specify any negative or positive number.

If you choose Date/Time for the value, specify the format that you want to use for the column. For more information about how to use a variable, see Time stamp variables.

For more information about column customizations, see Reference: Column customizations.

Schedule the connection

Connections can run at a highly configurable time interval, such as multiple times per hour, day, week, or month.

Important: Connections scheduled to run during an upgrade of Connect, or any Tanium solution configured as a connection source, might be interrupted or fail. Schedule your connections to run at a different time than your Tanium upgrades.
Note: If you do not enable the schedule, the connection only runs when you manually run it, unless you configure an Event source. Connections with Event sources only run when a configured event is detected, and cannot be scheduled or manually run.

Use the Schedule section to update the schedule:

  • Select Enable schedule.

  • In the Schedule Type, select Basic to build a schedule with the provided controls.

    Example connection schedule settings
  • To view or edit the cron expression directly, select Advanced - Define as a Cron Expression, and use the Advanced field to edit the cron expression.

    Example cron settings
Note: If a user that owns a scheduled connection is deleted, future scheduled instances of that connection do not run. For more information, see Issue: Scheduled connection owned by a deleted user no longer runs.

For more information about cron syntax, see Reference: Cron syntax for Connect.

Enable listening for an event

Connections with Event sources only run when a configured event is detected, and cannot be scheduled or manually run.

Use the Enablement section to send data when a configured event is detected:

  • Select Listen for this Event.

Save and verify connection

  1. After you enter the details for the connection, click Save.
    Tip: To save the connection and immediately run the connection, click Run and Save.

    If needed, resolve any errors or missing information. After the connection creates successfully, the connection details appear.

  2. To view details when the connection runs, click the Logs tab.
  3. To view an individual run log, expand the row table. For more information about how to resolve errors, see Troubleshooting.