Example: Parameterized sensors
Overview of parameterized sensors
A parameterized sensor requires you to enter input (parameter values) before the sensor can collect results from endpoints. You enter the parameter values when issuing a dynamic question that uses the sensor. For example, when you issue a question with the File Size sensor, Interact prompts you to specify the name of the file for which the sensor collects size information. The Tanium Server then creates an object called a temporary sensor, which contains the substituted parameter values. The Server uses the temporary sensor in the question that it sends to Tanium Clients. The Clients then run the sensor to return an answer.
For more information about entering parameter values when issuing questions and about saving questions with parameterized sensors, see Questions with parameterized sensors.
To create a parameterized sensor, configure the Scripts and Parameter Inputs as described in the following sections when you perform the steps in Create a sensor:
Sample question with parameterized sensor
File System Permissions is a Tanium-provided parameterized sensor. When you use that sensor in a dynamic question, Interact prompts you to specify values for the parameters File or Folder Path and Acknowledgement.
After you enter values and click Ask Question, the Tanium Server issues the question to Tanium Clients. When Clients return results, the Question Results page shows the question with the values that you entered and the grid shows the results.
For more examples of questions with parameterized sensors, see Questions with parameterized sensors.
Script for a parameterized sensor
You add a sensor script in the sensor configuration page, as described in Create a sensor. The script for a parameterized sensor has the requirements described in Parameter names and UTF-8 encoding and decoding.
Parameter names
In the script for a parameterized sensor, enclose input parameters with double vertical bars (||<parameter>||), such as ||Acknowledgement|| and ||Path|| in the following example of a PowerShell sensor. You must specify the same parameter names when you configure the Key field for Parameter Inputs in the sensor configuration, as described in Configure parameter inputs for a sensor.
UTF-8 encoding and decoding
When you issue a question with a parameterized sensor, The Tanium Server encodes the parameter values that you enter before passing the values to the sensor script. The Server includes the encoded values in the temporary sensor that it sends in the question to Tanium Clients. Clients then run the script to answer the question, and the script applies UTF-8 decoding to the encoded values.
PowerShell sensor scripts use the .NET method [System.Uri]::UnescapeDataString() to decode UTF-8 encoded parameters. For example, the script for the sensor File System Permissions uses that method for the parameter File or Folder Path:
$ItemPath = [System.Uri]::UnescapeDataString("||Path||")
Many sensor scripts in VBScript use a function for UTF-8 decoding, such as the following example.
'========================================
' UTF8Decode
'========================================
' Used to convert the UTF-8 style parameters passed from
' the server to sensors in sensor parameters.
' This function should be used to safely pass non english input to sensors.
'-----
'-----
Function UTF8Decode(str)
Dim arraylist(), strLen, i, sT, val, depth, sR
Dim arraysize
arraysize = 0
strLen = Len(str)
for i = 1 to strLen
sT = mid(str, i, 1)
if sT = "%" then
if i + 2 <= strLen then
Redim Preserve arraylist(arraysize + 1)
arraylist(arraysize) = cbyte("&H" & mid(str, i + 1, 2))
arraysize = arraysize + 1
i = i + 2
end if
else
Redim Preserve arraylist(arraysize + 1)
arraylist(arraysize) = asc(sT)
arraysize = arraysize + 1
end if
next
depth = 0
for i = 0 to arraysize - 1
Dim mybyte
mybyte = arraylist(i)
if mybyte and &h80 then
if (mybyte and &h40) = 0 then
if depth = 0 then
Err.Raise 5
end if
val = val * 2 ^ 6 + (mybyte and &h3f)
depth = depth - 1
if depth = 0 then
sR = sR & chrw(val)
val = 0
end if
elseif (mybyte and &h20) = 0 then
if depth > 0 then Err.Raise 5
val = mybyte and &h1f
depth = 1
elseif (mybyte and &h10) = 0 then
if depth > 0 then Err.Raise 5
val = mybyte and &h0f
depth = 2
else
Err.Raise 5
end if
else
if depth > 0 then Err.Raise 5
sR = sR & chrw(mybyte)
end if
next
if depth > 0 then Err.Raise 5
UTF8Decode = sR
End Function
In shell scripts, you can use a function similar to the following percent_decode function to decode the parameter data.
#!/bin/sh
percent_decode() {
local data=$(echo "$1" | sed 's/%/\\\x/g')
/usr/bin/printf '%b' "$data"
}
myVariable=`percent_decode "||parameter_value||"`
The printf utility might not be available or might not work correctly on all Linux, macOS, and UNIX platforms. The following implementation is more fool-proof but less elegant.
#!/bin/sh
brute_force_percent_decode() {
# decode everything between 0x20-0x7E except:
#0 1 2 3 4 5 6 7 8 9 (0x30-0x39)
#A B C D E F G H I J K L M N O P Q R S T U V W X Y Z (0x41-0x5A)
#a b c d e f g h i j k l m n o p q r s t u v w x y z (0x61-0x7A)
echo "$1" | sed -e 's/%20/ /g' \
-e 's/%21/!/g' \
-e 's/%22/"/g' \
-e 's/%23/#/g' \
-e 's/%24/$/g' \
-e 's/%25/%/g' \
-e 's/%26/\&/g' \
-e "s/%27/'/g" \
-e 's/%28/(/g' \
-e 's/%29/)/g' \
-e 's/%2[aA]/*/g' \
-e 's/%2[bB]/+/g' \
-e 's/%2[cC]/,/g' \
-e 's/%2[dD]/-/g' \
-e 's/%2[eE]/./g' \
-e 's#%2[fF]#/#g' \
-e 's/%3[aA]/:/g' \
-e 's/%3[bB]/;/g' \
-e 's/%3[cC]/</g' \
-e 's/%3[dD]/=/g' \
-e 's/%3[eE]/>/g' \
-e 's/%3[fF]/?/g' \
-e 's/%40/@/g' \
-e 's/%5[bB]/[/g' \
-e 's/%5[cC]/\\/g' \
-e 's/%5[dD]/]/g' \
-e 's/%5[eE]/^/g' \
-e 's/%5[fF]/_/g' \
-e 's/%60/`/g' \
-e 's/%7[bB]/{/g' \
-e 's/%7[cC]/|/g' \
-e 's/%7[dD]/}/g' \
-e 's/%7[eE]/-/g'
}
myVariable=`brute_force_percent_decode "||parameter_value||"`
Configure parameter inputs for a sensor
Parameter Inputs that you add to a sensor configuration determine the prompts that a user must complete when issuing a question with the sensor. When you Create a sensor, add each parameter that the Script for a parameterized sensor uses to reference the value that the user enters:
- On the sensor configuration page, go to the Parameters section and select . For descriptions of the types, see Parameter types.
- In the Key field, specify the parameter name that the script uses (see Parameter names) but without the double vertical bars (||) that enclose the parameter in the script. Console includes the bars automatically when you add a parameter to the sensor configuration. The figure Parameter inputs shows an example of the Path parameter.
- Enter a Label to identify the parameter in the Interact workbench when users issue a question.
- (Optional) Configure Options for the parameter. The options vary by parameter type. For more information, see Parameter options.
- (Optional) Configure Validation Expressions for the parameter types List, Text Area, and Text Input. For more information, see Validation expressions.
- Verify that the parameter looks and behaves as expected in the Preview section, which shows how users see the parameter when they issue a question. For example, you can enter values to test any limits that you configured in the Options.
Parameter types
The most common type of user-input widget for a parameter value is a text-entry field (Text Input type), but you can select any of the following types.
|
Parameter type |
Description |
|---|---|
|
Checkbox |
Users select a checkbox to enable a setting (set the parameter value to 1) or clear the checkbox to disable the setting (set the value to 0). |
|
Date |
Users enter a date or select a date through the Calendar widget |
|
Date Time |
Users enter a date and time or select a date and time through the Calendar |
|
Date Time Range |
Users specify a start date/time and end date/time. For the End Date setting, select Require if users must specify an end date/time or clear the checkbox if the end date/time is optional. Set the 1time standard to Local Time or UTC. |
|
Drop Down List |
Users select only one item from a drop-down list. To specify each value that users can select, go to the Values section, click + add value and enter the value. |
|
List |
Users enter one or more values and use a pipe "|" to delimit multiple values. Entering a value is optional instead of required if List Is Optional is selected in the parameter Options. To define the allowed values, see Validation expressions. |
|
Numeric |
Users enter a number. |
|
Numeric Interval |
Users enter a number and select the associated unit from a list. The unit has a numeric value (interval) that Interact multiplies by the user entry to determine the parameter value. For example, the list might include the units Seconds, Minutes, and Hours with the corresponding values 1, 60, and 3600 respectively. In this case, if a user enters 2 and selects Hours, the parameter value is 7200 (2 * 3600). To specify each unit that users can select, go to the Interval Units section, click + add interval, enter a label for the unit, and enter its value. |
|
Separator |
This type is not a parameter input but a graphical separator that helps users to distinguish different sections of the user input form when entering parameter values. If a user must specify multiple values, you can use sections to visually organize related parameters in the input form. The Separator text that you specify appears as the section title and has a line below it. |
|
Text Area |
Users enter a large amount of text that can include multiple lines. To define the allowed values, see Validation expressions. |
|
Text Input |
Users enter a single line of text. To define the allowed values, see Validation expressions. |
|
Time |
Users enter a time or select a time through the Clock widget |
|
1 Local Time is local to the system that you use to access Console. UTC is Coordinated Universal Time. 2 Now is the current date/time when users specify a value for the parameter. |
|
Parameter options
Use parameter Options to limit the range of values that users can enter, control how the Interact workbench presents a parameter, or provide help information that users see when entering values. The figure Parameter inputs shows an example of information that you can specify for a Text Input parameter to help users understand what to enter. The options that are available vary by parameter type. Only the Separator type has no options.
|
Parameter option |
Description |
Parameter types |
|---|---|---|
|
Date Limits |
Restrict user entries to within a minimum and/or maximum date. For each limit, select a Specific date through the Calendar widget |
Date Date Time |
|
Enable drill-down autofill |
This option applies only to parameterized sensors, not parameterized packages. Select the option to auto-populate a parameterized sensor in a drill-down question with the values of matching parameters in the results that the user selects in the Question Results grid. For more information, see Drill down into results. |
All types |
|
Default Start/End Date |
Specify a default start and/or end date. For each date, select a Specific date through the Calendar widget |
Date Time Range |
|
Provide Default Value |
Enter a default value to appear in the parameter input field. For list parameters, specify one value for each line. Users can overwrite the default value with a custom value. |
List Numeric Numeric Interval Text Area Text Input |
|
Provide Height in Lines |
Specify the vertical height of a text area parameter. This option controls only the display size of the text-entry field, not the number of lines that users can enter. For example, if you enter 3, the text-entry field appears 3 lines high but users can enter more than 3 lines of text. |
Text Area |
|
Provide Help Text |
This option adds an Information icon |
All types |
|
Provide Max Chars |
Specify the maximum number of characters that users can enter for the parameter value. |
Text Area Text Input |
|
Provide Maximum Value |
Specify the highest number that users can enter for the parameter. |
Numeric Numeric Interval |
|
Provide Minimum Value |
Specify the lowest number that users can enter for the parameter. |
Numeric Numeric Interval |
|
Provide Prompt Text |
Enter read-only text to appear in the parameter input field. The text is not a value for the parameter but typically explains what value to enter. If you also configure the Provide Default Value option, users initially see the default value and then see the prompt text only if they delete the default value. |
Text Area Text Input |
|
Provide Restrict Expression |
Enter a regular expression that defines the allowed values. For example, the expression A‑Za‑z allows alphabetic characters but not numbers or special characters.
Tip: You can also use Validation Expressions to define the allowed values. For more information, see Validation expressions.
|
List |
|
Provide Snap Interval |
Use this option if the parameter value that a user enters must be divisible by the snap interval value. |
Numeric Numeric Interval |
|
Provide Step Size |
Specify the amount by which users can increase or decrease the value of a numeric parameter. Enter a step size that is a multiple of the Provide Snap Interval value unless the snap interval is set to 0. |
Numeric Numeric Interval |
|
List Is Optional |
Select this option if entering a value for a List parameter is optional instead of required. |
List |
|
Selected |
Select this option for a Checkbox parameter that must be selected by default. Users can manually clear the checkbox. |
Checkbox |
|
Time Limits |
Restrict user entries to within a minimum and/or maximum time. For each limit, select a Specific time through the Clock widget |
Date Time Time |
Validation expressions
For the parameter types List, Text Area, and Text Input, you can add Validation Expressions to define the allowed values. The expressions are based on Perl Compatible Regular Expressions (PCRE). Boolean AND logic applies if you add fields for multiple expressions. You can apply Boolean OR logic to multiple expressions by entering them as a single field entry with pipes "|" as separators. Each expression field has an adjacent text box where you can enter a description to help users understand the expression. For example, if the expression is \S{5}, you might enter the help text Value must be at least 5 characters.