Reference: TanOS health check results

The TanOS health check provides an overview of the health of the TanOS environment on a Tanium Appliance. After initial configuration, TanOS automatically runs a health check every 15 minutes. The results for the latest health check are stored in the health.log file in the /outgoing directory. For information about manually running a health check, see Run the Health Check.

Best practice:

The health check sends alerts if they are enabled. As a best practice:

  • Enable alerts.

  • Configure a severity level for alerts that matches the checks for which you want to receive alerts. For information about specific alerts, including severity levels, see Reference: TanOS health check results.

  • Configure an SMTP destination to send email alerts.

  • (Optional) Configure a syslog destination.

For information about configuring alerts, see Configure syslog alerts.

Is EULA accepted

Table 1. TanOS EULA acceptance health check results

Check

Description

Severity

Condition

Remediation

Is EULA Accepted

Checks whether the end-user license agreement (EULA) has been accepted. Reports the user who accepted the EULA and the time at which it was accepted.

WARN

EULA not accepted

From the main menu, enter Q to view the EULA. Follow the prompts to review and accept the EULA.

Operating System health

Table 2. TanOS operating system health check results

Check

Description

Severity

Condition

Remediation

CPU

Checks for excessive processor usage across all cores. The reported value is snapshot of a single point in time.

Best practice: Use SNMP polling for continuous monitoring of processor utilization. For more information, see Configuring SNMP.

WARN

>90% average CPU usage across all processors

  • Review the CPU usage of running processes to determine whether certain processes might be consuming excessive processor time. Contact Tanium Support for assistance in troubleshooting such processes.

    Tip: You can use the htop command to monitor processes and resource usage.
  • After determining the cause of the issue, you can, as a temporary measure, restart Tanium services or reboot the Appliance. If possible, determine the cause before restarting to avoid delaying a diagnosis.

  • For a virtual Tanium Appliance or cloud-based Tanium Appliance, increase system resources.

Memory

Checks for low available RAM. Because of the way Linux manages memory, it is common for available RAM to be below 10% in production. However, if the RAM is full and the Appliance uses a significant amount of swap space, performance might degrade.

ERROR

No available memory

  • If the Swap check is 2 or lower, low available RAM is usually not a cause for concern.

  • If an ERROR condition is frequent for the Memory check, or if the Swap check is 3 or higher, review the following remediation recommendations:

    • Review the memory usage of running processes to determine whether certain processes might be using excessive memory. Contact Tanium Support for assistance in troubleshooting such processes.

      Tip: You can use the htop command to monitor processes and resource usage.
    • After determining the cause of the issue, you can, as a temporary measure, restart Tanium services or reboot the Appliance. If possible, determine the cause before restarting to avoid delaying a diagnosis.

    • For a virtual Tanium Appliance or cloud-based Tanium Appliance, increase available RAM.

WARN

<10% available memory

Swap

Indicates the concurrent I/O pages swapped per second.

INFO

N/A

Partition <partition name>

Checks the used space on disk partitions

Important: When disk usage exceeds 95% on a critical partition (/, /var, /log, or /opt), TanOS stops all Tanium services to preserve TanOS functionality.

ERROR

>95% disk usage on a critical partition (/, /var, /log, or /opt)

  • If any partition reports a WARN condition, determine what is using the space and reduce the size before filling up the partition. If necessary, contact Tanium Support for assistance.

  • For a virtual Tanium Appliance or cloud-based Tanium Appliance, increase available storage for the virtual machine or cloud instance, and then increase storage on the Appliance.

  • For a physical Tanium Appliance, contact Tanium Support for assistance.

WARN

>75% disk usage on any partition

Boot Check

Checks the boot type configured for the Appliance. TanOS must be configured for EFI boot on a physical Tanium Appliance. On a virtual Tanium Appliance or cloud-based Tanium Appliance, both EFI and BIOS boot are allowed.

INFO

BIOS boot with a physical Appliance

Contact Tanium Support for assistance.

GRUB key

Checks whether the GRUB key in use on the Appliance is valid.

WARN

Invalid GRUB key

Generate a new GRUB key. For more information, see Change the GRUB key password.

Active partition

Reports which partition set TanOS is using. This can be useful information when alternate partitions are in use for a physical Tanium Appliance or virtual Tanium Appliance. This check is informational and always reports a "pass" condition.

N/A

N/A

N/A

Upgrade

Checks whether a TanOS upgrade has failed

ERROR

Upgrade failed

Reattempt the TanOS upgrade. If the upgrade fails repeatedly, collect a Tanium Support Gatherer (TSG) bundle and contact Tanium Support.

Hardware health

Table 3. TanOS hardware health check results

Check

Description

Severity

Condition

Remediation

hardware type

Physical Tanium Appliance: Reports the hardware Appliance code

Virtual Tanium Appliance or cloud-based Tanium Appliance: Reports the virtual Appliance code

This check is informational and always reports a "pass" condition.

N/A

N/A

N/A

RAID controller <#> security key

Physical Tanium Appliance only: Checks whether the RAID controller security key is set, which is necessary for proper encryption of the RAID array.

WARN

RAID controller security key is not properly set

Contact Tanium Support for assistance.

disk encryption

Physical Tanium Appliance only: Checks the status of disk encryption in the RAID array.

WARN

Disk encryption not configured correctly

Contact Tanium Support for assistance

hardware SEL

Physical Tanium Appliance only: Checks the usage of the hardware system event log

ERROR

>90% of log space used

Sign in to the iDRAC virtual console as the tanremote user, and clear the hardware system event log.

User health

Table 4. TanOS user health check results

Check

Description

Severity

Condition

Remediation

user <username>

Checks that each TanOS user has the correct level of privileges for the role assigned to that user

ERROR

User privileges do not match the assigned role

Contact Tanium Support for assistance.

admin users

Checks that at least two users have been given the tanadmin role

INFO

Only one user has the tanadmin role assigned

Create another TanOS user with the tanadmin role.

system user policies

Checks that the security policies for each TanOS user match the user security policies that are configured for the Appliance

ERROR

A security policy for a user does not match the policy configured for the Appliance

Reapply the security policy that is not properly applied.

password expiration

Checks the password expiration date for each local TanOS user that can authenticate with a password. Reports a warning for a password that expires within 14 days or that must be changed at the next sign-in.

ERROR

A user password has expired

Change the password for the affected user. To change your own password, see Change the password for the current TanOS user. To reset the password for another user, see Reset a user password or enable password access.

MFA Policy

Checks that more than one authentication method is globally enabled for all users

WARN

Only one authentication method is configured globally

Require at least two of the available authentication methods: key authentication, password authentication, or multifactor (TOTP) authentication.

Network health

Table 5. TanOS network health check results

Check

Description

Severity

Condition

Remediation

own hostname resolution

Checks that the Appliance can resolve its own host name

INFO

DNS timeout or an unknown error occurred

Check that the DNS configuration is correct. Work with your network administrator to resolve DNS or other network issues, and perform another health check.

ERROR

Own host name cannot be resolved

Check that the host name and DNS configuration is correct. If the resolution relies on DNS, work with your network administrator to resolve DNS issues.

mount <module share>

Checks whether a configured module share is disconnected

ERROR

Module share is configured but not mounted

List and test module file share mounts. If necessary delete the mount and re-create it. For more information, see Configure solution module file share mounts.

Connection tracking

Checks the ratio of network connections to the maximum number allowed for the Appliance

INFO

>70% of available network connections in use

Contact Tanium Support to assist in determining the cause of the high number of connections.

Service health

Table 6. TanOS service health check results

Check

Description

Severity

Condition

Remediation

chronyd service

Checks that the time synchronization service is running and that the time is synchronized

ERROR

Service is not running or status cannot be determined

Check the status of the chronyd service, and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

WARN

Time not synchronized

host time

Virtual Tanium Appliance only: Checks the time difference between the host and virtual Appliance

WARN

Time difference >5s

  • Make sure that a valid time synchronization source is provided for the NTP configuration.

  • Make sure a valid time synchronization source is provided for the NTP configuration on your hypervisor host.

  • Restart the chronyd service.

rsyslog service

Checks that the rsyslog service is running

ERROR

Service is not running or status cannot be determined

Reboot the Appliance or reconfigure syslog forwarding to restart the rsyslog service.

syslog delivery

Checks whether the rsyslog service is successfully forwarding syslog messages to the configured destination

Note: This check can occasionally produce a false positive WARN condition due to a temporary increase in the outgoing message queue. Typically, remediation is necessary only if you observe a repeated or persistent WARN condition.

WARN

Messages have not been delivered (indicates number of failed messages)

syslog forwarding TLS

Checks whether certificate enforcement is properly configured for syslog forwarding if TLS is enabled for syslog forwarding

WARN

A misconfiguration exists that is preventing certificate enforcement for syslog forwarding with TLS enabled

Reconfigure syslog forwarding to resolve the misconfiguration.

iptables service

Checks whether the iptables service is running

ERROR

Service is not running or status cannot be determined

Reboot the Appliance. If the problem persists, contact Tanium Support for assistance.

ip6tables service

Checks whether the ip6tables service is running

ERROR

Service is not running or status cannot be determined

Reboot the Appliance. If the problem persists, contact Tanium Support for assistance.

sshd service

Checks whether the sshd service is running

ERROR

Service is not running or status cannot be determined

Check the status of the sshd service, and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

ipsec

Checks whether the ipsec service is running

Important: The ipsec service is required for an active-activeTanium Server or active passive Tanium Module Server configuration.

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the ipsec service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

sssd service

Checks whether the sssd service is running, and whether debug logging is enabled

Note: Running the sssd service with debug logging enabled could cause performance issues.

ERROR

Service is not running or status cannot be determined

From the main menu, enter C-A-T-S to check the status of the sssd service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure. For configuration information, see Configure LDAP authentication for TanOS system users.

INFO

Debug logging enabled

Contact Tanium Support for assistance.

local auth service

Checks whether the slapd service is running. The slapd service provides the local authentication service for Tanium Console users. Additionally, it always manages the default user tanium, even if you use Importing and authenticating users through LDAPLDAP authentication and do not otherwise use the local authentication service in TanOS.

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the slapd service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

Local LDAP config

Performs internal checks to evaluate the health of the local authentication service.

ERROR

Internal checks failed

  • From the main menu, enter C-L-C for more details about the LDAP content mismatch.

  • From the main menu, enter 1-M-E to restart replication, which resolves most LDAP configuration errors.

Remote LDAP config

Performs internal checks to evaluate the health of the local authentication service on the remote Appliance in a clustered environment

ERROR

Internal checks failed

LDAP contents

Checks that the local LDAP contents for the local authentication service match the remote LDAP contents in a clustered environment

ERROR

Local contents do not match remote contents

Application health

Table 7. TanOS application health check results

Check

Description

Severity

Condition

Remediation

TS

Tanium Server only: Checks whether the taniumserver service is running

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the taniumserver service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

TS database connection

Tanium Server only: Checks the Tanium Server connection to the database

ERROR

The Tanium Server cannot connect to the database

Contact Tanium Support for assistance.

TS database

Tanium Server only: Checks the size of the Tanium Server database

INFO

Database size >50GB

Contact Tanium Support for assistance.

TS database pg_wal

Tanium Server only: Checks the size of the PostgreSQL write-ahead log (WAL) directory

ERROR

pg_wal directory missing

Contact Tanium Support for assistance.

ERROR

pg_wal directory >50% of partition size

LDAP Sync

Tanium Server only: Checks LDAPS or StartTLS certificate configuration

WARN

LDAPS or StartTLS certificate validation is disabled

Check the Configure LDAP server connectionsLDAP configuration for the Tanium Server.

WARN

In a clustered environment, the LDAPS or StartTLS certificate configuration does not match the configuration on a peer

INFO

LDAPS or StartTLS certificates exist but are not in use

TMS

Primary Tanium Module Server only: Checks whether the taniummoduleserver service is running

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the taniummoduleserver service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

Secondary TMS

Secondary Tanium Module Server only: Checks whether the taniummoduleserver service is running. The service should be stopped on a secondary Module Server.

ERROR

Service is running or status cannot be determined

Use the Tanium Service Control menu to check the status of the taniummoduleserver service and stop it.

tanium-<solution-name>

Tanium Module Server only: Checks whether each installed solution service is running

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the service for the solution, and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

TMS database pg_wal

Tanium Module Server only: Checks the size of the PostgreSQL write-ahead log (WAL) directory

ERROR

pg_wal directory missing

Contact Tanium Support for assistance.

ERROR

pg_wal directory >50% of partition size

IPsec

Tanium Server in an active-active configuration or Tanium Module Servers in an active passive configuration: Checks that there is a secure connection between Tanium Servers in an active-active configuration

ERROR

Secure connection failed between Tanium Servers or Tanium Module Servers

Use the Tanium Service Control menu to restart the ipsec service if it is already running, or attempt to start it if it is not. If the service fails to start, review Status Details for more information about the failure.

Memory Plan

Tanium Server or Tanium Module Server only: Checks that the memory plan for the local database instance is set appropriately

WARN

Configured memory plan is not the preferred plan for the Appliance model (physical Tanium Appliance) or the available memory (virtual Tanium Appliance or cloud-based Tanium Appliance)

Configure the memory plan to the indicated preferred plan.

TZS

Tanium Zone Server only: Checks whether the taniumzoneserver service is running

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the taniumzoneserver service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

Zone Hub

Tanium Zone Server Hub only: Checks whether taniumzoneserver service is running

ERROR

Service is not running or status cannot be determined

Use the Tanium Service Control menu to check the status of the taniumzoneserver service , and attempt to start or restart it. If the service fails to start, review Status Details for more information about the failure.

TaniumServer file permissions

Tanium Server only: Checks for proper file permissions and ownership on Tanium Server files

WARN

Specified files do not have the proper permissions or ownership

Reinstall access control lists (ACLs).
TaniumModuleServer file permissions

Tanium Module Server only: Checks for proper file permissions and ownerships on Tanium Module Server files

WARN

Specified files do not have the proper permissions or ownership

Reinstall access control lists (ACLs).
TaniumZoneServer file permissions

Tanium Zone Server only: Checks for proper file permissions and ownership on Tanium Zone Server files

WARN

Specified files do not have the proper permissions or ownership

Reinstall access control lists (ACLs).

TanOS

Table 8. TanOS system health check results

Check

Description

Severity

Condition

Remediation

BIOS Version

Physical Tanium Appliance only: Checks whether the installed BIOS firmware version is up to date with the version available with the installed version of TanOS

WARN

Old version of firmware installed

Install the available firmware update.

PERC Version

Physical Tanium Appliance only: Checks whether the installed RAID controller firmware version is up to date with the version available with the installed version of TanOS

WARN

Old version of firmware installed

Install the available firmware update.

iDRAC Version

Physical Tanium Appliance only: Checks whether the installed iDRAC firmware version is up to date with the version available with the installed version of TanOS

WARN

Old version of firmware installed

Install the available firmware update.

NIC Version

Physical Tanium Appliance only: Checks whether the installed NIC firmware version is up to date with the version available with the installed version of TanOS

WARN

Old version of firmware installed

Install the available firmware update.

Backup

Tanium Server or primary Tanium Module Server only: Checks whether a system backup is scheduled to run

ERROR

Backup is scheduled, but an encryption key is not properly configured

Configure the encryption key for the backup.

INFO

No backup is scheduled

Configure an automatic backup.
Partition sync

Appliances with an inactive partition set: Checks whether a partition sync has been performed in the last 90 days

WARN

The fstab configuration file used to mount the inactive partition is missing

Perform a partition sync.

WARN

The partition sync time stamp is missing

INFO

>90 days since last partition sync

TanOS key material

Checks for issues with the cryptographic keys on the Appliance

ERROR

A required key is invalid, obsolete, or missing

Generate a new key for any keys that are indicated by the error.

TanOS version

Internet-connected Appliances: Checks whether a newer version of TanOS is available

INFO

A newer version of TanOS is available for upgrade

Upgrade TanOS to the new version.

TanOS version match

Appliances in an Array: Checks whether the TanOS version matches for all Array members

WARN

TanOS versions do not all match

Upgrade TanOS to the new version on all Array members.

Miscellaneous

Table 9. Miscellaneous TanOS health check results

Check

Description

Severity

Condition

Remediation

Core Files

Checks for core dumps that are stored on the Appliance from process crashes

Best practice: Copy core files from the Appliance to share with Tanium Support when requesting troubleshooting assistance. To save disk space, clean up core files that have been copied or are no longer needed.

WARN

Core files exist on the Appliance

Shell Keys

Checks whether a TanOS shell key is active for read-write restricted shell or full shell access

INFO

Shell key is active

Use the Shell Keys menu to remove shell access or revoke all shell keys when read-write restricted shell or full shell access is no longer needed.

Auth plugin

Tanium Server only: Checks whether the proper authentication plugin is in use

INFO

Deprecated or unsupported authentication plugin in use

Contact Tanium Support for assistance.

Database replication health

Table 10. TanOS database replication health check results

Check

Description

Severity

Condition

Remediation

Database Replication

Tanium Server or Tanium Module Server only: Checks the status of database replication

ERROR

Database replication failed

  • Review replication status.

  • From the main menu on the secondary Tanium Server or Module Server, enter 3-3-B to reinitialize the replication.

WARN

Database replication is in a start-up, catch-up, back-up, or stopping state

Allow time for the replication state to clear and then perform another health check.

TMS Database Stats Collection

Tanium Module Server only: Checks whether collection of database replication statistics is enabled

INFO

Collection of database replication statistics enabled

Disable collection of database replication statistics. Keep database replication statistics disabled when you are not troubleshooting a replication issue.

TMS sync health

Table 11. TanOS TMS sync health check results

Check

Description

Severity

Condition

Remediation

Tanium Module Server Sync Health

Tanium Module Server only: Checks whether Module Server synchronization is successful. If a Module Server file sync is in progress, the error is not reported until the sync has been running for more than 24 hours.

ERROR

Module Server synchronization failed, or a Module Server file sync has been running for more than 24 hours

Disk Encryption Key

Table 12. TanOS Disk Encryption Key health check results

Check

Description

Severity

Condition

Remediation

Disk Encryption Key check

Physical Tanium Appliance only: Checks whether the Disk Encryption Key has been exported

Important: The Disk Encryption Key is required to decrypt drives after a hardware failure.

WARN

Disk Encryption Key has not been exported

Export the Disk Encryption Key and store it in a safe location.

Postgres SSL health check

Table 13. TanOS Postgres SSL health check results

Check

Description

Severity

Condition

Remediation

Postgres SSL

Tanium Server only: Checks the TLS configuration of the local PostgreSQL database

ERROR

Missing DB Directory

Contact Tanium Support for assistance.

ERROR

TLS disabled for PostgreSQL database

SSL CRL file

Tanium Server only: Reports the name of the certificate revocation list (CRL) file if in use. This check is informational only.

N/A

N/A

N/A

OVA health

Table 14. TanOS OVA health check results

Check

Description

Severity

Condition

Remediation

Client Count

Virtual Tanium Appliance only: Reports the count of Tanium Clients that have connected during the current or prior day and checks whether the number exceeds the maximum recommended with current virtual machine resources

INFO

Number of connected Clients exceeds the recommended maximum

RAM Requirements

Virtual Tanium Appliance only: Checks whether the RAM configured for the virtual machine is less than the RAM recommended for the number of connected Clients

INFO

RAM less than recommended minimum

Increase virtual machine RAM. For more information, see Cloud-based Tanium Appliance and virtual Tanium Appliance specifications

CPU Requirements

Virtual Tanium Appliance only: Checks whether the number of CPU cores configured for the virtual machine is less than the CPU cores recommended for the number of connected Clients

INFO

CPU cores less than recommended minimum

Increase virtual machine CPU cores. For more information, see Cloud-based Tanium Appliance and virtual Tanium Appliance specifications