Tanium Appliance support and troubleshooting
View version information
When discussing issues, it is important to communicate precise version information with colleagues and with Tanium Support. This screen also provides other important information, such as system time, uptime, and basic network configuration details.
Run the Health Check
After initial configuration, TanOS automatically runs a health check every 15 minutes. The results for the latest health check are stored in the health.log file in the /outgoing directory.
The health check sends alerts if they are enabled. As a best practice:
-
Enable alerts.
-
Configure a severity level for alerts that matches the checks for which you want to receive alerts. For information about specific alerts, including severity levels, see Reference: TanOS health check results.
-
Configure an SMTP destination to send email alerts.
-
(Optional) Configure a syslog destination.
For information about configuring alerts, see Configure syslog alerts.
To run a health check manually:
Overview of Tanium Appliance logs, reports, and troubleshooting features
The following logs, reports, and troubleshooting features can help diagnose issues with the Appliance itself. For additional information about logs and troubleshooting for Tanium Core Platform Servers, see Tanium Core Platform troubleshooting and logs in an Appliance deployment.
-
About this Appliance screen: This screen provides information about the Tanium Appliance version, system time, uptime, and basic network configuration details.
-
Advanced Support menu: This menu provides options for exporting core files, generating process dumps, and viewing directory space usage.
-
Array roles log: This log records events that relate to installation of roles on Appliances.
-
Airgap log: This log records events that relate to an air gap installation.
-
Backup Restore log: This log records events that relate to the restoration of a core or comprehensive backup.
-
Cloud Access Point log: This log records access information for Tanium Clients that connect to Tanium Cloud through an Appliance with the Cloud Access Point role.
-
Database Operations menu: This menu provides options for viewing information about Tanium database operations.
-
Health Check report: This report provides information on the health of the Appliance operating system, hardware, users, network, services, applications, database replication, RAID security, Postgres SSL, and the virtual machine (if applicable).
-
iDRAC log The iDRAC log provides information about system events and firmware updates in the iDRAC interface.
-
Measure data transfer rate: You can measure the data transfer rate between an Array Manager and an Array member to help diagnose network issues between Appliances.
-
Network Diagnostics menu: This menu provides options for running network diagnostic procedures, viewing networking information, and viewing firewall details.
-
Network Latency log: This log records periodic tests of network latency to help monitor and diagnose network issues between Appliances.
-
Performance Monitoring menu: This menu provides options for viewing information about system activity, processes, input/output usage, CPU usage, and other resource usage.
-
Read-only restricted shell: Opening an RO shell enables you to view files on the Appliance file system, including logs that are not accessible through the TanOS console.
-
SNMP walk: You can configure integration with a Simple Network Management Protocol (SNMP) manager for collecting and analyzing Appliance information.
-
Status menu: This menu provides options for viewing information about system activity, processes, input/output usage, CPU usage, and other resource usage.
-
Syslog forwarding: You can forward Appliance logs to a remote syslog server.
-
Tanium Support Gatherer: The Tanium Support Gatherer (TSG) provides information on the status of the Appliance system, processes, and network interfaces.
-
TanOS event log: This log records major events on the Appliance, such as Server installations, upgrades, initial configuration, software resets, backups, partition synchronization, Tanium Module Server synchronization, Tanium Core Platform services stopped due to lack of disk space, Tanium Server or Module Server failover, and restricted or unrestricted shell access.
-
TanOS partition sync log: This log records events that relate to partition synchronization on Appliances with active and inactive partitions.
-
TanOS upgrade log: This log records events that relate to Appliance upgrades.
-
TCP dump: Running a TCP dump creates a packet capture (PCAP) file for the network interface that you select. PCAP files capture real-time data packets that traverse a network. You can use the files to analyze network traffic and troubleshoot network issues.
Restart services or networking
Check whether a Tanium service needs to be restarted. You can use the TanOS menu to stop a service whether the service is enabled, and you can use TanOS to start a service if the service is enabled.
Restart services
Restart networking
- Sign in to the TanOS console as a user with the tanadmin role.
- Enter A-2 (Appliance Configuration > Networking Configuration).
- Enter 4 to restart networking.
Exit maintenance mode after an error
Some maintenance procedures that you perform in TanOS automatically enter maintenance mode to ensure Tanium services are not affected by the maintenance operation. When the operation completes, TanOS automatically exits maintenance mode and resumes normal operations. However, if an error occurs during a maintenance operation, TanOS can sometimes stay in maintenance mode. If TanOS indicates that you are unable to perform an operation due to maintenance activity, you can manually exit maintenance mode.
- Sign in to the TanOS console as a user with the tanadmin role.
- Enter B-C (Appliance Maintenance > Maintenance Mode).
- Enter 1 to clear any maintenance actions.
Reinitialize replication
Use this procedure after the secondary database server has been promoted to primary, or to reinitialize a broken Tanium cluster.
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 2-B (Tanium Operations > Cluster Configuration).
-
Enter E and follow the prompts to reinitialize replication.
Reindex databases
Use this procedure to reindex databases as directed by Tanium Support, or if you encounter database-related issues in solution logs after a TanOS upgrade.
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 3-3-I (Tanium Support > Database Operations > Reindex Databases), and follow the prompt to reindex all databases.
Review TanOS Appliance logs
TanOS Appliance logs record events related to TanOS operations, such as Appliance configuration, installation of roles, TanOS upgrades, status and failures from previous health checks, and other operations at the OS level.
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 3-1-1 (Tanium Support > Logs > TanOS Appliance).
-
Select a log from the menu.
-
Select an item to view the log, follow its growth, delete it, or export it to the /outgoing directory.
Review Tanium Core Platform logs
If you are diagnosing issues with the Tanium Core Platform installation, review the logs. For additional information about logs and troubleshooting for Tanium Core Platform Servers, see Tanium Core Platform troubleshooting and logs in an Appliance deployment.
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 3-1 (Tanium Support > Logs).
-
Enter 2 for Tanium Server, 3 for Tanium Module Server, or 4 for Tanium Zone Server, depending on the role of the Appliance.
CODE------------------------------------------------------ >>> Tanium Support -> Logs -> taniumserver <<< 1: Tanium Server Log (log0.txt) 2: Tanium Server TDL Log (log0.txt) 3: Tanium Server RBAC Log (rbac0.txt) 4: Tanium Server PAM4 Log (tanium_pam4.log) 5: Tanium Server Workbenches (workbenches_manager.log) 6: Tanium Server Signature Verifier (signature_verifier.log) 7: Tanium Server DB Upgrade Log (database-upgrade0.txt) 8: Tanium Server Auth0 Log (auth0.txt) 8: Tanium Module History Log (module-history0.txt) R: Return to previous menu RR: Return to top ------------------------------------------------------ -
Select an item to view the log, follow its growth, delete it, or export it to the /outgoing directory.
CODE------------------------------------------------------ >>> Tanium Support -> Logs -> TaniumServer -> log0.txt <<< Size: 538 Last Update: 2022-03-11 14:10:40 V: View file F: Follow log file growth T: Delete content of logfile E: Export to outgoing (sftp) R: Return to previous menu RR: Return to top ------------------------------------------------------
Review Tanium solution module logs
If you are diagnosing issues with expected behavior for solution modules, examine the module logs on the Module Server.
-
Sign in to the TanOS console on the Module Server as a user with the tanadmin role.
-
Enter 3-2 (Tanium Support > Module Log Files Access).
-
Select a log from the menu.
-
Select an item to view the log, follow its growth, delete it, or copy it to the /outgoing directory.
Review the configuration
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 2-2 (Tanium Operations > Configuration Settings).
-
Use the menu to view and edit Tanium Core Platform Server configuration files.
Run Tanium Support Gatherer
The Tanium Support Gatherer (TSG) collects system status, process status, network interface status, and so on, to help Tanium Support evaluate possible Appliance or Tanium Core Platform Server issues.
Each Tanium Core Platform Server has a predefined list of files and commands to gather relevant data. The TSG output files are placed in the SFTP outgoing directory. The output files are ZIP archives, named with their collection or module name and a datestamp. The files remain in the outgoing directory until a daily cleanup task removes them. From the TSG menu, you specify a single item (a module or collection of files) or a comma-separated list of items.
Copy core files
Run tcpdump
Running a TCP dump creates a packet capture (PCAP) file for the network interface that you select. PCAP files capture real-time data packets that traverse a network. You can use the files to analyze network traffic and troubleshoot network issues.
You can add filters to the report to control how much data is captured. You can also see a preview of the report before you run the command.
Run network diagnostics
Use the Network Diagnostics menu to run basic diagnostic procedures.
Ping a remote system
- Sign in to the TanOS console of the Appliance as a user with the tanadmin role.
- Enter 3-4-F (Tanium Support > Run Network Diagnostics > Ping Remote System).
- Enter the IP address or fully qualified domain name (FQDN) of the system to ping to view connection information.
Test a connection using a remote port
The Test Remote Port screen allows you to attempt a connection to a given destination and port using TCP.
- Sign in to the TanOS console of the Appliance as a user with the tanadmin role.
- Enter 3-4-2 (Tanium Support > Run Network Diagnostics > Test Remote Port (TCP)).
- Enter the IP address or FQDN of the destination to test.
- Enter the port number for the connection. The TanOS console indicates whether the Appliance can successfully connect using the specified port.
Trace the connection path to a destination
Use the Trace Path screen to run a traceroute command to a remote destination using a specified connection protocol.
- Sign in to the TanOS console of the Appliance as a user with the tanadmin role.
- Enter 3-4-3 (Tanium Support > Run Network Diagnostics > Trace Path).
- Enter the protocol to use for the connection, the FQDN or IP address of the destination, and the port to view the connection path between the Appliance and the destination.
Resolve a host name
- Sign in to the TanOS console of the Appliance as a user with the tanadmin role.
- Enter 3-4-4 (Tanium Support > Run Network Diagnostics > Resolve Name).
- Enter the FQDN to find its IP address.
Check IPSEC
- Sign in to the TanOS console of the Appliance with the secondary database as a user with the tanadmin role.
- Enter 3-4 (Tanium Support > Run Network Diagnostics).
- Enter 5 to view information about any active IPsec tunnels.
Listening ports
- Sign in to the TanOS console of the Appliance with the secondary database as a user with the tanadmin role.
- Enter 3-4 (Tanium Support > Run Network Diagnostics).
- Enter 6 to view a list of all detected listening ports.
Show firewall
- Sign in to the TanOS console of the Appliance with the secondary database as a user with the tanadmin role.
- Enter 3-4 (Tanium Support > Run Network Diagnostics).
- Enter 7 to view firewall details.
View network latency between Array members
View current network latency
- Sign in to the TanOS console of the Appliance with the secondary database as a user with the tanadmin role.
- Enter 3-4 (Tanium Support > Run Network Diagnostics).
- Enter 8 to view the latency between the current Appliance and other Array members.
View network latency history
- Sign in to the TanOS console of the Appliance with the secondary database as a user with the tanadmin role.
- Enter 3-1-1-11 (Tanium Support Menu > Tanium Log Files > TanOS Appliance > Network Latency Log).
- Enter V to view the current log file, or enter the line number of a previous log file if the relevant log entries have been rotated out of the current log file.
Measure the data transfer rate between an Array Manager and an Array member
You can measure the data transfer rate between an Array Manager and another Appliance in the Array to help diagnose network issues between Appliances.
-
Sign in to the TanOS console as a user with the tanadmin role.
-
Enter 1-M (Tanium Installation > Appliance Array).
-
Enter the line number for the Appliance with which to measure the data transfer rate.
-
Enter N to begin the measurement.
Examine Tanium and TanOS files
In rare cases, you or Tanium Support might need to examine Tanium and TanOS files written to the file system.
Open read-only restricted shell
Request read-write restricted shell or full shell access
You must follow a special procedure to request read-write restrictive shell access or full shell access.
Security of Tanium Appliances
Tanium prioritizes security in all of its products, and the Appliance is no exception. Appliances are built on a minimal OS and include only the packages and services needed to support the Tanium Platform. Appliances are configured with secure defaults, most of which cannot be reduced or disabled. A Security Technical Implementation Guide (STIG) is available from the U.S. Defense Information Systems Agency (DISA) that you can use to validate that all exposed configuration settings are in a secure state.
Tanium releases appliance updates on a regular basis to ensure that packages are up to date and contain the latest fixes. Software bills of material (SBOMs) are available for Tanium Appliance and the Tanium Platform.
Tanium performs regular penetration tests and secure code reviews as part of our overall product security strategy. An attestation document, verifying the penetration tests performed on Tanium Appliances by a third party, is available on request.
Security scanners and antivirus tools are not allowed on Tanium Appliances
The Tanium Appliance is a closed, hardened system intended to run only Tanium software and supporting services. To maintain performance, stability, and security of the Tanium Platform, installation and execution of third-party software is not allowed. Access to the underlying operating system is restricted.
If your compliance, security, or audit process requires information that is not available in the UI, APIs, or menu system, contact Tanium Support and provide information about your requirements so that we can understand enhancements that you might need in the Tanium Appliance. Accessing the underlying operating system to run manual or automated scans or audits is not supported.
Support for Tanium Appliances
To contact Tanium Support for help, sign in to the Tanium Customer Community.
For more information about how to submit a support case, see Case Submission Form.
TanOS support lifecycle
Tanium routinely provides security patches, feature improvements and bug fix repairs to TanOS Appliances via in-place upgrades, incrementing TanOS versions forward. These upgrades are the only way to ensure your Tanium Appliance is patched against the latest security vulnerabilities and known software issues, since Tanium only releases versions forward and does not release patches against previously released versions. Tanium offers a fixed date lifecycle policy for Tanium Appliances. Physical hardware support terms are different and can be found in the Hardware Terms and Conditions.
In order to be able to provide support for Tanium Appliances, the TanOS version must not be older than 18 months from the date of release. Customers are required to upgrade TanOS versions that have reached end of support prior to Tanium working on a support case. Customers are strongly encouraged to stay on the latest release of TanOS to ensure they are using the most secure and functional Tanium Appliance product available.
For TanOS versions that are beyond the support lifecycle term, Tanium offers commercially reasonable support as follows:
-
Commercially reasonable support incidents will be provided through Tanium Support. If the support incident requires escalation to development for further guidance or requires a non-security or a security update, then customers will be asked to upgrade to a fully supported TanOS version.
-
Commercially reasonable support does not include an option to engage Tanium product development resources; technical workarounds may be limited or not possible.
Tanium customers are expected to use the provided upgrade paths to maintain TanOS at a supported version on an ongoing basis. Previous TanOS release dates can be viewed in the release notes to determine if a given version is still within the Tanium support window.
Support information for physical Tanium Appliances
For detailed information about support for physical Tanium Appliances, review your hardware support terms with Tanium. To receive ongoing support services for physical Appliances, renew the annual support and maintenance services on each Appliance. Customers can renew support and maintenance services for a maximum of 6 years from the original purchase date. Tanium Support is always the primary contact for all Tanium Appliance concerns, including hardware issues.
All physical Tanium Appliances include self-encrypting hard drives that are FIPS 140-2 Validated. During initial setup, each Appliance creates a unique encryption key, stored on the RAID controller of the Appliance and not the individual drives. Only you the customer can access, export, or change this key. Because the data on the drive remains encrypted if a drive is removed from an Appliance, no other system can access the data on the drive, and the drive must be reformatted before reuse. Failed hard drives are typically returned to the Appliance hardware OEM. If you choose to keep a failed drive, additional charges might apply.