Known issues for 2025H2 release

Tanium Threat Response: Live Response destinations with invalid data fail to load

Symptoms

Live Response destinations with invalid Amazon S3 or Microsoft Azure configuration data fail to load in the Threat Response workbench. If a Live Response destination contains an invalid value for an Amazon S3 bucket or Azure storage account, the destination now fails validation.

  • The Destinations list fails to load and returns a validation error instead of showing your destinations.
  • Generating Live Response package fails.

Resolve this issue

Contact Tanium Support to correct the invalid destination value through the API. There is no workaround within the Threat Response workbench.

Tanium Patch: Update 14 reimports test detectoid data

Symptoms

If you use a WSUS server to source patches and the server still has the test detectoid data (included in KB5121986), 2025H2 Update 14 causes Tanium Scan for Windows to reimport the test detectoid data.

Resolve this issue

Delete the test detectoid data from the WSUS server, then upgrade to 2025H2 Update 15.

Tanium Reveal: File Snippets page might show blank data during initial connection

Symptoms

On File Snippets page, the list of affected files in the Results section might not appear correctly. This issue occurs more frequently when connected to one or more endpoints.

Resolve this issue

Refresh the page, or click Back to Results and then return to the File Snippets page.

TanOS 1.8.6.0124: iDRAC SNMP can break after running firmware update check

Symptoms

When SNMP is enabled on iDRAC, the following actions may cause SNMP to stop working:

  • Performing an upgrade
  • Checking for firmware updates
  • Running a self test

Cause

This issue occurs because the update process temporarily disables the iDRAC SNMP user and changes its password. As a result, SNMP polling fails and monitoring tools might report connectivity issues.

Resolve this issue

Re-enter your desired SNMP password to reconfigure iDRAC SNMP.

After you complete this step, SNMP resumes normal operation until the next firmware update check or upgrade.

Airgap Tanium Appliance: Tanium Solutions upgrade does not start in Tanium Console when an airgap All-in-One (AIO) appliance is upgraded from SAR25H1 to SAR25H2

Symptoms

During the upgrade, AIO appliances installing Airgap show the following error:

Errors were reported by Airgap installer. Therefore manifest URLs listed above were not automatically assigned.

Cause

This issue happens because TanOS searches /opt/Tanium for a Python file and uses the first one found by timestamp. TanOS mistakenly selects a Python copy from TPAN, which is incompatible for installation, causing a silent error.

Resolve this issue

After hitting the error when loading modules via airgap after the upgrade, remove the Health Check module and restage the airgap bundle in TanOS via the 2 > C > 1 menu. These actions remove the TPAN Python file and allow the installation to complete successfully.

Tanium Connect: Editing email server profile fails

Symptoms

When editing and saving an existing email server profile, the following error occurs: There was an error saving the email server profile config.

This error also removes all existing configurations for the profile.

Resolve this issue

No resolution available at this time. Create a new email server profile to use in connections.

TanOS 1.8.6.0124: restorecon message shown when upgrading platform

Symptoms

When upgrading to Platform 7.8.2, restorecon might not be able to set a context label and will display a warning message:

restorecon: Could not set context for /opt/Tanium/TaniumServer/Downloads/18e227d92404379292b0414300474524975f5b53bb543460d85931b35269e1f1: No such file or directory

Resolve this issue

This message does not reflect an error and the upgrade can continue as is.

Tanium Health Check: Failure to install or update on non-English Windows-based Tanium Module Servers or Tanium Servers

Symptoms

The installation or update of Tanium Health Check as part of this SAR release might fail on non-English Windows-based Tanium Module Servers or Tanium Servers.

Resolve this issue

Tanium will resolve this issue in a future maintenance release. If you need this update urgently, contact Tanium Support for the updated version.

Tanium Health Check 1.13.98 and 1.13.100: TPAN fails to create on Windows servers

Symptoms

When creating a TPAN on a Windows server based Tanium instance, the TPAN generation could fail.

Resolve this issue

No resolution at this time. This issue will be resolved in the next maintenance release.

TanOS 1.8.6.0134: iDRAC Users error can block physical appliance upgrade

Symptoms

If you upgrade to TanOS 1.8.6.0134 and have never set up SNMP, the following error message appears on the physical appliances: ERROR: Could not get iDRAC.Users.4.UserName

Resolve this issue

Use menus A-5-S and A-5-D to start and stop SNMP, if it is not already enabled. These steps will create the missing user account on the iDRAC before the upgrade.

TanOS 1.9.0: Upgrade to 1.9.0 is blocked after the June 2025H1 or June 2025H2 maintenance release

Symptoms

After you apply the June maintenance release for TanOS 1.8.5 (2025H1) or 1.8.6 (2025H2), the appliance cannot upgrade to the June 2026H1 release (1.9.0). TanOS refuses the upgrade because it prevents upgrades that move to a release with an earlier build date, and the June 2025H1 and 2025H2 maintenance releases are dated later than the June 2026H1 (1.9.0) build.

Resolve this issue

This will be resolved in the next maintenance release.