Eleven Considerations When Administering Tanium Connect

Tanium gives enterprises instant access to all of their endpoints at scale, which has changed the way our customers think about and interact with large volumes of data. But sometimes our customers need to export endpoint data outside of Tanium. This is where Connect becomes useful.

Connect lets you send large amounts of data from Tanium on a regular basis. Here are some ideas on getting the most value out of Connect:

  1. Keep Connect up to Date. As with all modules, read the release notes of new Connect updates as Tanium continues to add features and make performance improvements.

  2. Create a process for onboarding Connections. The process should include testing in a QA environment and promotion into Production. Testing should validate that the data is valid and is in the format that the end consumer desires. Connect supports limiting data to specific computer groups (i.e. allowing a rollout of Connection data to percentages such as 5, 10, 50, 100% of endpoints). 

  3. Limit Connections to Active Business Use Cases. Limit the number of new connections in production to ensure they are necessary and have an active business use case. Consider questions available to our Splunk application and working with your TAM / Unified Endpoint Security (UES) team on questions that might be of high value.

  4. Consider Filtering New Connections. When adding a new connection, consider if using a filter is a good idea or not. Tanium can send only new events or filter out certain events. Filtering out events will save you bandwidth from the module server and storage on the remote system.

  5. Limit Users to Required Functions. Use RBAC to limit to least necessary permissions for job function. Consider training for any Connect user or administrator.

  6. Perform Periodic Connection Review. Perform periodic review of connections for rationalizations as use cases may change.

  7. Avoid Column Renames. In general, column renames should be carefully considered or avoided if possible as it adds a good bit of computational strain on the module server.

  8. Space out Connections. Review the timing of connections to space out run times evenly. This will help ensure Connections can complete on time and do not use too many resources on the module server.

  9. Rollout Signals Slowly and Tune. Since Signals are events, perform slow rollout of Signals to allow for proper tuning prior to being sent via Connect. 

  10. Monitor Health / Connections. Review failed Connections and work with Tanium support for Connections that consistently fail.

  11. Garbage In, Garbage Out.*Data sent via Connect is only as good as the data being sent to Connect. If you would not ask the question in Tanium, it is probably not a good idea to run it on a scheduled basis via Connect.

As always, every environment is unique and there will be circumstances where some of these best practices may not directly apply or be a true best practice.