Announcing Tanium Client 7.7
Tanium Client 7.7 Release Announcement
Tanium Client 7.7 is now available for download or deployment through Tanium Client Management.
New features of the 7.7 client include:
-
Expansion of the endpoint identifier, ComputerID, from 32-bits to 64-bits, increasing the ID space to allow for namespaces, new managed endpoint types, and increased stability for tracking endpoints over time.
-
Support for CXSocket, which allows the creation of a direct communication channel to the client over the Tanium protocol, allowing for direct connect experiences to in the future operate using the Tanium protocol instead of an additional port and connection.
-
RedirectionGuard is enabled in auditing mode when running on supported Windows versions.
Improvements and bug fixes for this release can be found in Release Notes Tanium Client (Version 7.7.3.8176).
Important Considerations for Upgrading to the 7.7 Client Version
The new features of Tanium Client 7.7 include an expansion of the ComputerID endpoint identifier from 32-bits to 64-bits to allow for namespaces and new managed endpoint types. The expansion of ComputerID is coupled with increased stability for tracking endpoints over time and integration of ComputerID into Tanium protocol to provide increased integrity of answer results reported by the client.
When you upgrade existing Tanium Clients to Tanium Client 7.7, that client's current 32-bit ComputerID will be retained. New Tanium Client 7.7 installs will be issued a ComputerID which is larger than 2^32 and therefore will always be larger than in previous versions.
If you have integrations or custom content configured for your environment, review the functionality of those items before you upgrade. Expansion of ComputerID to 64-bit may cause issues with integrations that store ComputerID without enough space for the new 64-bit identifier and custom content that reads the ComputerID value as a string or an integer. This includes the following items:
-
Tanium Connect destinations using ComputerID
-
API Integrations using ComputerID
-
Sensors, packages, and other content using ComputerID
You can deploy a single Tanium Client 7.7 to a newly installed endpoint for a ComputerID larger than what can fit in a 32-bit field for testing.
If you have no external integrations or custom content configured in your environment, no additional preparation is required to accommodate the expanded ComputerID.
Upgrading to Tanium Client 7.7
No endpoints will be upgraded to Tanium Client 7.7 automatically. Environments with a configured Latest Available 7.6 version client upgrade deployment in Client Management will not upgrade clients beyond the latest Tanium Client 7.6 release. You can deploy an upgrade to existing Tanium Clients by selecting the Latest Available 7.7 version option from the Client Version dropdown on the Edit Client Upgrade page. You can also download the 7.7 Tanium Client directly from the Tanium Client Management Module.
Customers using the recommended Endpoint Configuration Change Management option to upgrade clients alongside toolset manifests will continue to receive Tanium Clients no later than version 7.6 until Tanium Client 7.7 becomes the default manifest client after June 2025.